![Moxa Technologies MDS-G4000 Series Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/moxa-technologies/mds-g4000-series/mds-g4000-series_quick-installation-manual_1842641013.webp)
- 13 -
NOTE
Using a shielded cable achieves better electromagnetic
resistance.
NOTE
When grounding, we suggest using the cable type - AWG
(American Wire Gauge) 16 (1.31 mm
2
).
RS-232 with RJ45 Interface Console Connection
The switch has an RS-232 serial console with an RJ45 interface. Use a
Moxa 9-pin female console cable to connect to your PC's COM port (or
via USB-to-Serial converters or hubs). You can then use a console
terminal program, such as Moxa’s PComm Terminal Emulator, to access
the console configuration utility of the switch.
RS-232 Setup:
•
Baud rate: 115,200
•
Data Bits: 8
•
Parity: None
•
Stop Bits: 1
•
Terminal Type: VT100
USB Connection
The USB connection is reserved for functions that may be required in
the future.
Pin Description
1
VCC (+5V)
2
D- (Data-)
3
D+ (Data+)
4
GND (Ground)
The Reset Button (Diameter 0.9 mm)
The reset button can perform two functions. One is to reset the switch
to factory default settings and the other is to reboot the switch if the
button has been depressed and release immediately.
Reset to Factory Default Settings
Depress the Reset button for five seconds to load the factory default
settings. Use a pointed object, such as a straightened paper clip or
needle (the diameter must not exceed 0.9 mm), to depress the Reset
button. When you do so, the STATE LED will start to blink about four
times per second. Continue to depress the STATE LED until it begins
blinking more rapidly; this indicates that the button has been depressed
for five seconds and you can release the Reset button to load factory
default settings.
NOTE
DO NOT power off the switch when loading default settings.