background image

ioMirror E3210 

User’s Manual 

www.moxa.com/product

First Edition, May 2007 

 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

Moxa Technologies Co., Ltd. 

Tel: +886-2-8910-1230 
Fax: +886-2-8910-1231 
Web: 

www.moxa.com

 

Moxa Technical Support 

Worldwide: 

[email protected]

The Americas:  [email protected]
 

 

Содержание ioMirror E3210

Страница 1: ...s Manual www moxa com product First Edition May 2007 Moxa Technologies Co Ltd Tel 886 2 8910 1230 Fax 886 2 8910 1231 Web www moxa com Moxa Technical Support Worldwide support moxa com The Americas s...

Страница 2: ...itment on the part of MOXA MOXA provides this document as is without warranty of any kind either expressed or implied including but not limited to its particular purpose MOXA reserves the right to mak...

Страница 3: ...Grounding the Unit 2 2 Connecting to the Network 2 2 Connecting the I O Device 2 2 Setting the IP Address 2 3 Static or Dynamic IP 2 3 Factory Default Settings 2 3 Modifying IP Address 2 4 Chapter 3 U...

Страница 4: ...1 ioMirror E3210 Modbus Mapping B 1 0xxxx Read Write Coils Functions 1 5 15 B 1 1xxxx Read Only Coils Function 2 B 1 3xxxx Read Only Registers Function 4 B 1 4xxxx Read Write Registers Functions 3 6 1...

Страница 5: ...ions involve using a pair of ioMirror servers one on each end of the connection The following topics are covered in this chapter Welcome Features Infrastructure Examples Ethernet Network Fiber Optic N...

Страница 6: ...cted from one ioMirror to another with only 20 ms signal latency over a local area network Industrial Business Automation Applications The ioMirror is a fast and easy way to connect input and output s...

Страница 7: ...f ioMirror I O servers Wiring plans are now easier than ever y No programming and no separate PLC or PC controller A separate PLC or PC controller is not required for ioMirror operation No ladder or C...

Страница 8: ...Optic Network Wireless LAN Package Checklist Standard Accessories y ioMirror E3210 peer to peer Ethernet I O server y Document and Software CD Optional Accessories y LDP1602 ioMirror LCD display kit N...

Страница 9: ...gic 0 0 to 3 VDC Logic 1 10 to 30 VDC DI COM to DI Isolation 3K VDC 2 KVrms Common Type 8 points 1 COM Digital Output Channels 8 points sink type I O Mode Digital Output On state Voltage 24 VDC nomina...

Страница 10: ...VDC Wiring I O cable max 14 AWG Environmental Operating Temperature 10 to 60 C Storage Temperature 40 to 85 C Certifications Shock Free fall Vibration CE Class A Level 3 Criteria B FCC Part 15 CISPR E...

Страница 11: ...ioMirror E3210 User s Manual Introduction Physical Dimensions 1 7 Units mm 12 22 5 95 9 51 79 93 02 121 8 115 10 98 9 5 40 39 10 7 39 5 46 51...

Страница 12: ...y Reset Button The reset button is used to load factory defaults Use a pointed object such as a straightened paper clip or toothpick to hold the reset button down for 5 seconds The Ready LED will turn...

Страница 13: ...EDs Orange Live 10Mbps Ethernet connection Green Live 100Mbps Ethernet connection Ethernet Flashing Transmitting or receiving data System LEDs Red Power is on PWR Off Power is off Red System error Gre...

Страница 14: ...0 peer to peer Ethernet I O server The following topics are covered in this chapter Connecting the Hardware Connecting the Power Grounding the Unit Connecting to the Network Connecting the I O Device...

Страница 15: ...until the system is ready Grounding the Unit Connect your grounding line to the wall mount sockets or DIN rail Connecting to the Network For initial installation connect the ioMirror to the same LAN...

Страница 16: ...signed in your network environment y For a static IP environment you can enter a specific IP address using ioMirrorAdmin or the web console y In a dynamic IP environment BOOTP or DHCP you can use ioMi...

Страница 17: ...mware Please refer to Chapter 4 for instructions on using ioMirrorAdmin The web console is a configuration tool that is opened using a standard web browser through a localor network connection Please...

Страница 18: ...eb console The following topics are covered in this chapter Overview Opening the Web Console Navigation Quick Reference Basic Settings Network Settings General Settings Ethernet Configurations I O Set...

Страница 19: ...ple if you click on Basic Settings in the navigation panel the main window will show a page of basic settings that you can configure You can enter configuration changes directly on the page Click on t...

Страница 20: ...ure digital output channels ioMirror Settings Configure channel module mapping alarm system System Management Accessible IP Settings Filter access by IP address Network Connection Show TCP connections...

Страница 21: ...P address to be dynamically assigned by DHCP DHCP BOOTP or BOOTP I O Settings DI Channels Settings On the DI Channel Settings page you may view the status of each DI digital input channel Click a chan...

Страница 22: ...t no determines the network port that is used for I O signal transmission You can modify this setting as necessary to transmit signals through a firewall Time out determines how long the ioMirror will...

Страница 23: ...sing Acceptable Remote Module IP Address System Management Accessible IP Settings On the Accessible IP Settings page you may control who has configuration access to the ioMirror by entering the permit...

Страница 24: ...ging The connecting protocol for each connection is indicated under Connection Type Web HTTP indicates a web console connection to the ioMirror ioMirror TCP indicates a connection to another ioMirror...

Страница 25: ...Load Factory Default On the Load Factory Default page you may reset the ioMirror back to its factory default settings Save Restart On the Save Restart page you may save all configuration changes and r...

Страница 26: ...anage your ioMirror server over the network The following topics are covered in this chapter Overview Installation ioMirrorAdmin Searching for ioMirror Servers Wiring Guide ioMirror Configuration Firm...

Страница 27: ...upgrade the firmware or refer to the unit s wiring guide y ioEventLog receives and stores error messages from ioMirror units on the network Installation To install ioMirrorAdmin and ioEventLog run SET...

Страница 28: ...nit on the network to use any of ioMirrorAdmin s functions In the System menu select Auto Scan Remote I O Server This opens a search window which automatically searches the network for ioMirror server...

Страница 29: ...guide select Wiring Guide from the Help menu ioMirror Configuration The ioMirror s web console can be opened within ioMirrorAdmin Select the desired unit in the left panel The unit s web console will...

Страница 30: ...rver on the network Right click the desired unit in the left panel and select Reset to Default ioEventLog Basic Functions ioEventLog is installed along with ioMirrorAdmin from the Document and Softwar...

Страница 31: ...can modify this setting as necessary to receive signals through a firewall It will need to match the settings for the ioMirror server that is being monitored The Log Directory is where the log files w...

Страница 32: ...e that you wish to view The logs for the day that you select will be displayed in the Alarm Log Viewer window Clearing the Log If you wish to clear the log you can select Clear from the Log menu This...

Страница 33: ...An e in the upper right hand corner of the display indicates that the parameter can be modified Press the center button to modify that parameter s settings Menu Options Display Explanation Actions ioM...

Страница 34: ...ss to ping If you get a timeout error it indicates that the unit cannot reach that IP address Otherwise the display will show the response time y ip address y ping ip ioMirror E3210 save restart Enter...

Страница 35: ...wer On Value 0 Off 1 On 00016 0x000F 1 bit CH7 DO Power On Value 0 Off 1 On 00017 0x0010 1 bit CH0 DO Safe Mode Value 0 Off 1 On 00018 0x0011 1 bit CH1 DO Safe Mode Value 0 Off 1 On 00019 0x0012 1 bit...

Страница 36: ...2 word Get all DI channels POWER ON status 38385 to 38432 0x20C0 8384 to 8431 48 word Get all DO channels POWER ON status 38433 to 38504 0x20F0 8432 to 8503 72 word Get all DI channels SAFE MODE statu...

Страница 37: ...x CUsed Network Port Numbers ioMirror E3210 Network Port Usage Port Type Usage 80 TCP Web Server 502 TCP Modbus Communication 68 UDP BOOTPC 68 UDP DHCP 4045 TCP ioMirror 4040 TCP ioEventLog 4800 UDP A...

Страница 38: ...uration for the ioMirror E3210 is as follows IP address 192 168 127 254 Netmask 255 255 255 0 Gateway 0 0 0 0 Alarm system Disable Time out 5 sec DI mode DI Filter time 0 5 ms DO mode DO DO alarm stat...

Страница 39: ...EPinouts and Cable Wiring The following topics are covered in this appendix Port Pinout Diagrams Ethernet Port Pinouts Digital I O Structure Digital Input Structure Digital Output Structure Alarm Outp...

Страница 40: ...oMirror E3210 User s Manual Pinouts and Cable Wiring Port Pinout Diagrams Ethernet Port Pinouts Pin Signal 1 Tx 2 Tx 3 Rx 6 Rx Digital I O Structure Digital Input Structure Digital Output Structure E...

Страница 41: ...ioMirror E3210 User s Manual Pinouts and Cable Wiring Alarm Output Structure E 3...

Отзывы: