Specifications of EDS-P510A-8PoE Series 

Technology 

Standards 

IEEE 802.3af/at for Power-over-Ethernet, 
IEEE 802.3 for 10BaseT, 
IEEE 802.3u for 100BaseT(X) and 100Base FX, 
IEEE 802.3ab for 1000BaseT(X), 
IEEE 802.3z for 1000BaseSX/LX/LHX/ZX, 
IEEE 802.3x for Flow Control, 
IEEE 802.1D for Spanning Tree Protocol, 
IEEE 802.1w for Rapid STP, 
IEEE 802.1Q for VLAN Tagging, 
IEEE 802.1p for Class of Service, 
IEEE 802.1X for Authentication, 
IEEE 802.3ad for Port Trunk with LACP 

Protocols 

IGMPv1/v2, GVRP, SNMPv1/v2c/v3, DHCP 
Server/Client, BootP, TFTP, SNTP, SMTP, RARP, 
GMRP, LACP, RMON, HTTP, HTTPS, Telnet, Syslog, 
DHCP Option 66/67/82, SSH, SNMP Inform, 
Modbus/TCP, EtherNet/IP, LLDP, IEEE 1588 PTP, 
IPv6 

MIB 

MIB-II, Ethernet-Like MIB, P-BRIDGE MIB, 
Q-BRIDGE MIB, Bridge MIB, RSTP MIB, RMON MIB 
Group 1, 2, 3, 9 

Flow Control 

IEEE 802.3x flow control, back pressure flow control 

Switch Properties 

Priority Queues 

Max. Number of 
Available VLANs 

64 

VLAN ID Range 

VID 1 to 4094 

IGMP Groups 

256 

Interface 

RJ45 Ports 

10/100BaseT(X) or 10/100/1000BaseT(X) auto 
negotiation speed 

Fiber Ports 

100/1000BaseSFP slot 

Console Port 

RS-232 (RJ45) 

LED Indicators 

PWR1, PWR2, FAULT, 10/100M (TP port), G1/G2 
(Gigabit port), MSTR/HEAD, CPLR/TAIL, PoE+ 

DIP Switch 

Turbo Ring, Master, Coupler, Reserve 

Alarm Contact 

Two relay outputs with current carrying capacity of 
0.5A @ 48 VDC 

Digital Input 

Two inputs with the same ground, but electrically 
isolated from the electronics 

 

For state “1”: +13 to +30V 

 

For state “0”: -30 to +3V 

 

Max. input current: 8 mA 

PoE (per port) 

Max. Output Power  15.4W in 802.3af, 30W in 802.3at, 36W in high 

power mode 

Output Voltage 

46 to 57 VDC (depends on external power supply) 

Max. Output Current 350 mA in 802.3af, 600 mA in 802.3at, 720 mA in 

high power mode 

Max. Overload 
Protection 

850 mA 

Содержание EtherDevice EDS-P510A-8PoE Series

Страница 1: ...2013 Moxa Inc All rights reserved P N 1802005100020 Moxa EtherDeviceTM Switch EDS P510A 8PoE Series Hardware Installation Guide First Edition January 2013...

Страница 2: ...th high EMI immunity The Ethernet switches support a variety of management functions including STP RSTP TurboRing Turbo Chain PoE power management PoE device auto checking PoE power scheduling IGMP VL...

Страница 3: ...o port 8 Gigabit port speed LED 9 Model name 10 SmartPoE LED indicator of PoE ports 11 Fast Ethernet port speed LED 12 10 100Mbps IEEE 802 3af at port 13 Terminal block for digital input 14 Terminal b...

Страница 4: ...he DIN Rail attachment plate to the EDS P510A 8PoE make sure the stiff metal spring is situated towards the top as shown by the following figures STEP 1 Insert the top of the DIN Rail into the slot ju...

Страница 5: ...of the screws should be less than 6 0 mm in diameter and the shafts should be less than 3 5 mm in diameter as shown in the figure on at right NOTE Before tightening the screws into the wall make sure...

Страница 6: ...alculate the maximum possible current in each power wire and common wire Observe all electrical codes dictating the maximum current allowable for each wire size If the current goes above the maximum r...

Страница 7: ...ct FAULT The relay contacts of the 2 pin terminal block connector are used to detect user configured events The two wires attached to the fault contacts form an open circuit when a user configured eve...

Страница 8: ...g protocol was developed by Moxa to provide better network reliability and faster recovery time Moxa Turbo Ring s recovery time is less than 300 ms Turbo Ring or 20 ms Turbo Ring V2 compared to a 3 to...

Страница 9: ...ust enable the Turbo Ring function first before using the DIP switch to activate the Master and Coupler functions NOTE If you do not enable any of the EDS P510A 8PoE switches to be the Ring Master the...

Страница 10: ...nking Data is being transmitted at 10 Mbps Off TP port s 10 Mbps link is inactive Port 1 to Port 8 100M GREEN On TP port s 100 Mbps link is active Blinking Data is being transmitted at 100 Mbps Off TP...

Страница 11: ...up 1 2 3 9 Flow Control IEEE 802 3x flow control back pressure flow control Switch Properties Priority Queues 4 Max Number of Available VLANs 64 VLAN ID Range VID 1 to 4094 IGMP Groups 256 Interface R...

Страница 12: ...00 M higher altitude available on demand Regulatory Approvals Safety UL508 Traffic Control NEMA TS2 Railway EN 50121 4 EMI FCC Part 15 CISPR EN55022 class A EMS EN61000 4 2 ESD Level 3 EN61000 4 3 RS...

Отзывы: