EDS-518A Series User’s Manual
Featured Functions
3-6
Speed
Setting
Description
Factory Default
Auto
Allows the port to use the IEEE 802.3u protocol
to negotiate with connected devices. The port and
connected devices will determine the best speed
for that connection.
100M-Full
100M-Half
10M-Full
10M-Half
Choose one of these fixed speed options if the
opposing Ethernet device has trouble
auto-negotiating line speed.
Auto
FDX Flow Ctrl
This setting enables or disables the flow control capability of this port when the “port transmission
speed” setting is in “auto” mode. The final result will be determined by the “auto” process
between EDS-518A and connected devices.
Setting
Description
Factory Default
Enable
Enables flow control for this port when in
auto-negotiate mode.
Disable
Disables flow control for this port when in
auto-negotiate mode.
Disable
MDI/MDIX
Setting
Description
Factory Default
Auto
Allows the port to auto detect the port type of the
opposing Ethernet device and change the port
type accordingly.
MDI
MDIX
Choose the MDI or MDIX option if the opposing
Ethernet device has trouble auto-negotiating port
type.
Auto
Network
The
Network
configuration allows users to modify the usual TCP/IP network parameters. An
explanation of each configuration item follows.