background image

 

- 13 - 

 

EDS-510A Series DIP Switches 

 

The default setting for each DIP Switch is OFF. The 
following table explains the effect of setting the DIP 
Switch to the ON position. 

 

“Turbo Ring” DIP Switch Settings 

DIP 1 

DIP 2 

DIP 3 

DIP 4 

Reserved for 
future use. 

ON: Enables this 
EDS as the Ring 
Master. 

ON: Enables the 
default “Ring 
Coupling” ports. 

ON: Activates 
DIP switches 1, 2, 
3 to configure 
“Turbo Ring” 
settings. 

OFF: This EDS 
will not be the 
Ring Master. 

OFF: Do not use 
this EDS as the 
ring coupler. 

OFF: DIP 
switches 1, 2, 3 
will be disabled. 

 

“Turbo Ring V2” DIP Switch Settings   

DIP 1 

DIP 2 

DIP 3 

DIP 4 

ON: Enables the 
default “Ring 
Coupling 
(backup)” port. 

ON: Enables this 
EDS as the Ring 
Master. 

ON: Enables the 
default “Ring 
Coupling” port. 

ON: Activates 
DIP switches 1, 
2, 3 to configure 
“Turbo Ring V2” 
settings. 

OFF: Enables the 
default “Ring 
Coupling 
(primary)” port. 

OFF: This EDS 
will not be the 
Ring Master. 
 

OFF: Do not use 
this EDS as a ring 
coupler. 

OFF: DIP 
switches 1, 2, 3 
will be disabled. 

 

NOTE 

You must enable the Turbo Ring function first before using the 
DIP switch to activate the Master and Coupler functions. 

 

 

NOTE 

If you do not enable any of the EDS-510A switches to be the Ring 
Master, the Turbo Ring protocol will automatically choose the 
EDS-510A with the smallest MAC address range to be the Ring 
Master. If you accidentally enable more than one EDS-510A to be 
the Ring Master, these EDS-510A switches will auto-negotiate to 
determine which one will be the Ring Master. 

 

 
 

 

Содержание EtherDevice EDS-510A Series

Страница 1: ... 2014 Moxa Inc All rights reserved P N 1802005100015 EDS 510A Hardware Installation Guide Moxa EtherDevice Switch Eighth Edition April 2014 ...

Страница 2: ... Pluggable transceiver with 1000BaseLX LC 10km 0 to 60 C SFP 1GLXLC T Small Form factor Pluggable transceiver with 1000BaseLX LC 10km 40 to 75 C SFP 1GLHXLC Small Form factor Pluggable transceiver with 1000BaseLHX LC 40 km 0 to 60 C SFP 1GLHXLC T Small Form factor Pluggable transceiver with 1000BaseLHX LC 40 km 40 to 75 C SFP 1GZXLC Small Form factor Pluggable transceiver with 1000BaseZX 80 km LC ...

Страница 3: ...seSX LX LHX ZX port EDS 510A 3SFP 1000BaseSX LX LHX ZX port 4 G3 EDS 510A 3GT 10 100 1000BaseT X port EDS 510A 1GT2SFP 1000BaseSX LX LHX ZX port EDS 510A 3SFP 1000BaseSX LX LHX ZX port 5 G1 G2 G3 LED indicators for 1000 Mbps ports 6 PWR1 LED for power input 1 7 PWR2 LED for power input 2 8 FAULT LED indicator 9 MSTR HEAD LED indicator 10 CPLR TAIL LED indicator 11 100M LED indicator for TP port 12...

Страница 4: ...tion orifices 4 DIP switches for Ring Master Ring Coupler and Turbo Ring 5 6 pin terminal block for DI 1 DI 2 and PWR 2 6 6 pin terminal block for PWR1 Relay 1 and Relay 2 Rear Panel 1 Screw holes for Wall Mounting Kit 2 DIN Rail Kit Mounting Dimensions Unit mm inch ...

Страница 5: ...the wall as shown in the following illustrations STEP 1 Remove the aluminum DIN Rail attachment plate from the rear panel of the EDS 510A and then attach the wall mount plates with M3 screws as shown in the figure at the right STEP 2 Mounting the EDS 510A on the wall requires 4 screws Use the EDS 510A with wall mount plates attached as a guide to mark the correct locations of the 4 screws The head...

Страница 6: ...ISIONS SHALL BE MADE EITHER IN EXTERNAL TO THE APPARATUS TO PREVENT THE RATED VOLTAGE BEING EXCEEDED BY THE TRANSIENTS DISTURBANCES OF MORE THAN 40 Wiring Requirements WARNING Do not disconnect modules or wires unless power has been switched off or the area is known to be non hazardous The devices may only be connected to the supply voltage shown on the type plate The devices are designed for oper...

Страница 7: ...nal or communications wiring and power wiring through the same wire conduit To avoid interference wires with different signal characteristics should be routed separately You can use the type of signal transmitted through a wire to determine which wires should be kept separate The rule of thumb is that wiring that shares similar electrical characteristics can be bundled together You should separate...

Страница 8: ... circuit when a user configured event is triggered If a user configured event does not occur the fault circuit remains closed Wiring the Redundant Power Inputs The EDS 510A has two sets of power inputs power input 1 and power input 2 The top two contacts and the bottom two contacts of the 6 pin terminal block connector on the EDS 510A s top panel are used for the two digital inputs The top and fro...

Страница 9: ...rams Pinout Diagrams and Cable Wiring Diagrams that convey information about the ports and the cables used to connect the EDS 510A to other devices Pinouts The Pinouts diagrams display the type of signal passing through each of the port s pins Cable Wiring The Cable Wiring diagrams present standard cable wiring schemes for cables used to connect the EDS 510A s ports to other devices These diagrams...

Страница 10: ...ND 8 CTS 9 DTR 10 RJ45 10 pin to DB9 F Cable Wiring 10 100BaseT X Ethernet Port Connection The 10 100BaseT X ports located on the EDS 510A s front panel are used to connect to Ethernet enabled devices Most users configure these ports for Auto MDI MDI X mode in which case the port s pinouts are adjusted automatically depending on the type of Ethernet cable used straight through or cross over and th...

Страница 11: ...Rx 3 Tx 6 Tx RJ45 8 pin to RJ45 8 pin Straight through Cable Wiring RJ45 8 pin to RJ45 8 pin Cross over Cable Wiring 1000BaseT Ethernet Port Connection 1000BaseT data is transmitted on differential TRD signal pairs over copper wires MDI MDI X Port Pinouts Pin Signal 1 TRD 0 2 TRD 0 3 TRD 1 4 TRD 2 5 TRD 2 6 TRD 1 7 TRD 3 8 TRD 3 ...

Страница 12: ...same line with the same letter A to A and B to B as shown below or A1 to A2 and B1 to B2 LC Port Pinouts LC Port to LC Port Cable Wiring ATTENTION This is a Class 1 Laser LED product To avoid causing serious damage to your eyes do not stare directly into the Laser Beam Turbo Ring DIP Switch Settings EDS 510A series are plug and play managed redundant Ethernet switches The proprietary Turbo Ring pr...

Страница 13: ...kup port ON Enables this EDS as the Ring Master ON Enables the default Ring Coupling port ON Activates DIP switches 1 2 3 to configure Turbo Ring V2 settings OFF Enables the default Ring Coupling primary port OFF This EDS will not be the Ring Master OFF Do not use this EDS as a ring coupler OFF DIP switches 1 2 3 will be disabled NOTE You must enable the Turbo Ring function first before using the ...

Страница 14: ...linking The EDS 510A has become the Ring Master of the Turbo Ring or the Head of the Turbo Chain after the Turbo Ring or the Turbo Chain is down Off When the EDS 510A is not the Master of this Turbo Ring or is set as the Member of the Turbo Chain CPLR TAIL GREEN On When the EDS 510A coupling function is enabled to form a back up path or when it s set as the Tail of the Turbo Chain Blinking When th...

Страница 15: ...s PWR1 PWR2 FAULT 10 100M TP port 1000M MSTR HEAD CPLR TAIL Alarm Contact Two relay outputs with current carrying capacity of 1A 24 VDC Digital Input Two inputs with the same ground but electrically isolated from the electronics For state 1 13 to 30V For state 0 30 to 3V Max input current 8 Ma Optical Fiber 1000BaseSX LX LHX ZX SX LX LHX ZX Wavelength 850 nm 1310 nm 1310 nm 1310 nm Max Tx 4 dBm 3 ...

Страница 16: ...t Reverse Polarity Protection Present Mechanical Casing IP30 protection metal case Dimensions W H D 80 5 135 105 mm 3 17 5 31 4 13 in Weight 1 17 kg Installation DIN Rail Wall Mounting Kit optional Environment Operating Temperature 0 to 60 C 32 to 140 F standard models 40 to 75 C 40 to 185 F wide temp models Storage Temperature 40 to 85 C 40 to 185 F Ambient Relative Humidity 5 to 95 non condensin...

Страница 17: ...icas Toll free 1 888 669 2872 Tel 1 714 528 6777 Fax 1 714 528 6778 Moxa China Shanghai office Toll free 800 820 5036 Tel 86 21 5258 9955 Fax 86 21 5258 5505 Moxa Europe Tel 49 89 3 70 03 99 0 Fax 49 89 3 70 03 99 99 Moxa Asia Pacific Tel 886 2 8919 1230 Fax 886 2 8919 1231 ...

Отзывы: