EDS-505A/508A Series DIP Switches
2
1
------
MASTER
COUPLER
TURBO
RING
4
3
The default setting for each DIP Switch is OFF. The
following table explains the effect of setting the DIP
Switch to the ON position.
“Turbo Ring” DIP Switch Settings
DIP 1
DIP 2
DIP 3
DIP 4
ON: Enables this
EDS as the Ring
Master.
ON: Enables the
default “Ring
Coupling” ports.
ON: Activates
DIP switches 1,
2, 3 to configure
“Turbo Ring”
settings.
Reserved for
future use.
OFF: This EDS
will not be the
Ring Master.
OFF: Do not use
this EDS as the
ring coupler.
OFF: DIP
switches 1, 2, 3
will be disabled.
“Turbo Ring V2” DIP Switch Settings
DIP 1
DIP 2
DIP 3
DIP 4
ON: Enables the
default “Ring
Coupling
(backup)” port.
ON: Enables this
EDS as the Ring
Master.
ON: Enables the
default “Ring
Coupling” port.
ON: Activates
DIP switches 1,
2, 3 to configure
“Turbo Ring V2”
settings.
OFF: Enables the
default “Ring
Coupling
(primary)” port.
OFF: This EDS
will not be the
Ring Master.
OFF: Do not use
this EDS as a
ring coupler.
OFF: DIP
switches 1, 2, 3
will be disabled.
NOTE
You must enable the Turbo Ring function first before using the DIP
switch to active the Master and Coupler functions.
NOTE
If you do not enable any of the EDS-505A/508A switches to be the
Ring Master, the Turbo Ring protocol will automatically choose the
EDS-505A/508A with the smallest MAC address range to be the
Ring Master. If you accidentally enable more than one
EDS-505A/508A to be the Ring Master, these EDS-505A/508A
switches will auto-negotiate to determine which one will be the
Ring Master.
LED Indicators
There are several LEDs on the EDS’s front panel. The function of each LED is
described in the following table.
LED Color
State
Description
PWR1
AMBER
On
Power is being supplied to power
input PWR1.