background image

 

- 12 - 

 

ATTENTION 

This is a Class 1 Laser/LED product. To avoid causing serious 
damage to your eyes, do not stare directly into the Laser Beam. 

 

Reset Button 

There are two functions available on the Reset Button. One is to reset 
the Ethernet switch to factory default settings by pressing and holding 
the Reset button for 5 seconds. Use a pointed object, such as a 
straightened paper clip or toothpick, to depress the Reset button. This 
will cause the STATE LED to blink once a second. After depressing the 
button for 5 continuous seconds, the STATE LED will start to blink 
rapidly. This indicates that factory default settings have been loaded 
and you can release the reset button. The other function is to reboot 
the device by depressing the reset button for less than five seconds. 

Turbo Ring DIP Switch Settings 

The EDS devices are plug-and-play managed redundant Ethernet 
switches. The proprietary Turbo Ring protocol was developed by Moxa 
to provide better network reliability and faster recovery time. Moxa 
Turbo Ring’s recovery time is less than 50 ms (

Turbo Ring V2

) —

compared to a 3- to 5-minute recovery time for commercial switches—
decreasing the possible loss caused by network failures in an industrial 
setting. 
There are five Hardware DIP Switches for Turbo Ring on the bottom 
panel of the EDS device that can help setup the Turbo Ring easily 
within seconds. If you do not want to use a hardware DIP switch to 
setup the Turbo Ring, you can use a web browser, telnet, or console to 
disable this function. 

NOTE 

Please refer to the 

Turbo Ring

 section in User's Manual for 

more detail information about the setting and usage of 

Turbo 

Ring V2

 

Turbo Ring DIP Switch Settings

 

 

The default setting for each DIP Switch is OFF. The 
following table explains the effect of setting the DIP 
Switch to the ON position. 
Remove the rubber cover on the bottom panel of 
the device to expose the DIP switches. 

 

 

 

Содержание EDS-4014 Series

Страница 1: ...02040140010 1802040140010 EDS 4014 Series Quick Installation Guide Moxa EtherDevice Switch Version 1 0 March 2022 Technical Support Contact Information www moxa com support 2022 Moxa Inc All rights re...

Страница 2: ...nt product pages located on Moxa s website www moxa com Default Settings IP address 192 168 127 253 Subnet Mask 255 255 255 0 Username admin Password moxa Panel Views of EDS 4014 Series Front Panel Vi...

Страница 3: ...3 Bottom Panel View 1 microSD card slot currently disabled 2 Reset button 3 DIP switches for Turbo Ring Ring Master and Ring Coupler Mounting Dimensions...

Страница 4: ...rt the upper lip of the DIN rail into the DIN rail mounting kit STEP 2 Press the EDS device towards the DIN rail until it snaps into place Removal STEP 1 Pull down the latch on the mounting kit with a...

Страница 5: ...6 0 mm in diameter and the shafts should be less than 3 5 mm in diameter as shown in the figure on at right NOTE Before tightening the screws into the wall make sure the screw head and shank size are...

Страница 6: ...um current allowable for each wire size If the current goes above the maximum ratings the wiring could overheat causing serious damage to your equipment Be sure to read and follow these important poin...

Страница 7: ...esponding pin type cable terminals NOTE The wire must be able to withstand at least 105 C and the torque value should be 4 5 lb in 0 51 N m NOTE We suggest the length of the pin type cable terminal is...

Страница 8: ...dels products there are two power inputs for redundancy for the high voltage HV models products there is only one power input Refer to the instructions and diagram below on how to connect the wires to...

Страница 9: ...er to tighten the wire clamp button on the front of the terminal block connector STEP 3 Insert the plastic terminal block connector prongs into the terminal block receptor which is located on the EDS...

Страница 10: ...TS 8 DTR USB Connection NOTE The USB function is currently reserved and may be required in the future It should be noted that this port cannot be used for charging any devices 10 100BaseT X Ethernet P...

Страница 11: ...ntrary to electrical signals optical signals do not require a circuit in order to transmit data Consequently one of the optical lines is used to transmit data from device I to device II and the other...

Страница 12: ...aged redundant Ethernet switches The proprietary Turbo Ring protocol was developed by Moxa to provide better network reliability and faster recovery time Moxa Turbo Ring s recovery time is less than 5...

Страница 13: ...ches to be the Ring Master the Turbo Ring protocol will automatically choose the EDS switch with the smallest MAC address range to be the Ring Master If you accidentally enable more than one switch to...

Страница 14: ...switch has become the Master of Turbo Ring after Turbo Ring has gone down 2 The switch is set as Head of Turbo Chain and Turbo Chain has gone down 3 The switch is set as the Turbo Ring s Member and th...

Страница 15: ...nking 4 times sec When the port s data is being transmitted at 10 100Mbps Off When the port is inactive or link down 100M 1000M SFP port Green On When the port is active and links at 1 000Mbps Blinkin...

Страница 16: ...ifferent power module refer to the specifications of the corresponding model For example if you replace the power module of the EDS 4014 LV T with the PWR 105 HV I refer to the specifications of the E...

Страница 17: ...Safety UL 61010 2 201 EN 62368 1 LVD EMC EN 55022 24 EN 61000 6 2 6 4 EMI FCC Part 15 Subpart B Class A EMS EN 61000 4 2 ESD Level 4 EN 61000 4 3 RS Level 3 EN 61000 4 4 EFT Level 4 EN 61000 4 5 Surg...

Отзывы: