DA-681A Series 

Quick Installation Guide 

x86 Rackmount Embedded Computers 

Edition 1.0, November 2015 

Technical Support Contact Information 

www.moxa.com/support 

Moxa Americas: 
Toll-free: 1-888-669-2872 
Tel:  1-714-528-6777 
Fax:  1-714-528-6778 

Moxa China (Shanghai office): 
Toll-free: 800-820-5036 
Tel:  +86-21-5258-9955 
Fax:  +86-21-5258-5505 

Moxa Europe: 
Tel:  +49-89-3 70 03 99-0 
Fax:  +49-89-3 70 03 99-99 

Moxa Asia-Pacific: 
Tel:  +886-2-8919-1230 
Fax:  +886-2-8919-1231 

Moxa India: 
Tel:  +91-80-4172-9088 
Fax:  +91-80-4132-1045 

 

 

 

 

 

 

 2015 Moxa Inc. All rights reserved. 

 

 

Содержание DA-681A Series

Страница 1: ...com support Moxa Americas Toll free 1 888 669 2872 Tel 1 714 528 6777 Fax 1 714 528 6778 Moxa China Shanghai office Toll free 800 820 5036 Tel 86 21 5258 9955 Fax 86 21 5258 5505 Moxa Europe Tel 49 89 3 70 03 99 0 Fax 49 89 3 70 03 99 99 Moxa Asia Pacific Tel 886 2 8919 1230 Fax 886 2 8919 1231 Moxa India Tel 91 80 4172 9088 Fax 91 80 4132 1045 2015 Moxa Inc All rights reserved ...

Страница 2: ...he DA 681A has a mini PCIe socket for mSATA and comes with Linux pre installed Windows 7 Embedded is also supported by the CTOS process Another plus is that the serial ports come with 2 kV digital galvanic isolation protection to guarantee communication reliability in harsh industrial environments In addition the state of art IEC 61850 3 IEEE 1613 and IEC 60255 compliance all in one design provide...

Страница 3: ...o the screws and then fasten the screws to the unit Refer to the following figure for detailed information DPP and DPP T Models SP Models AC Terminal AC Terminal DC Terminal DC Terminal NOTE 1 Disconnect all power supply cords before performing maintenance on the product 2 Fuses fuse F1 F2 T6 3A 500VAC 400VDC should be replaced by a qualified Moxa RMA service technician ...

Страница 4: ... to the negative terminal if the power source is DC or to the Neutral terminal if the power source is AC 3 NC Reserved for future customization 4 Signal Ground Signal Ground should be connected to the ground terminal for AC power source 1 5 COM COM pin for the alarm relay 6 NO Normal Open pin for the alarm relay 7 Signal Ground Signal Ground should be connected to the ground terminal for AC power ...

Страница 5: ...gabit Ethernet mode Off Not operating or in 10 Mbps Ethernet mode Programmable 1 6 Green Defined by user Reset Button Pressing the Reset button initiates a warm reboot The button plays the same role as a desktop PC s reset button After pressing the reset button the system will reboot automatically Note that all unsaved data will be lost when you push the reset button Connecting to a Display Your D...

Страница 6: ... 7 127 255 255 255 0 LAN 6 192 168 8 127 255 255 255 0 Configuring the Ethernet Interface Linux users should follow these steps If you use the console cable to configure network settings for the first time use the following commands to edit the interfaces file First take all network interfaces offline before you reconfigure the LAN settings ifdown a Next edit the network interfaces file you may us...

Страница 7: ...255 0 broadcast 192 168 3 255 The second LAN interface LAN 2 auto eth1 iface eth1 inet static address 192 168 4 127 netmask 255 255 255 0 broadcast 192 168 4 255 Exit VI by typing wq After the interfaces file has been configured use the following commands to reinitialize the network interfaces and activate the new settings immediately sync ifup a Win7 users should follow these steps Step 1 Go to S...