![Moxa Technologies AWK-4121 Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/moxa-technologies/awk-4121/awk-4121_user-manual_1842389008.webp)
AirWorks AWK-4121 User’s Manual
Introduction
‧
10 to 48V for state “1” (ON)
‧
Max. input current: 8 mA
Console
RS-232 (RJ45 type)
LAN Port
10/100BaseT(X) auto negotiation speed
LED Indicators
PWR, FAULT, STATE, WLAN and LAN
Power
Input Voltage
12 to 48 VDC, redundant dual DC power inputs or
48 VDC Power-over-Ethernet (IEEE 802.3af)
Input Current
0.494 to 0.121 A
Input Current (@ 24VDC)
0.3 A
Overload Current Protection 1.6 A
Reverse Polarity Protection Present
Mechanical
Dimensions
224 x 147.7 x 66.5 mm (8.82 x 5.82 x 2.62 in)
Weight 1.2
kg
Installation
Wall Mounting or DIN-Rail (with optional wall mounting kit)
Casing
IP67 protection, aluminum case
Environment
Operating Temperature:
-40 to 75°C (-40 to 167°F)
Storage Temperature:
-40 to 85ºC (-40 to 185ºF)
Ambient Relative Humidity 5 to 95% (non-condensing)
Regulatory Approvals*
Radio:
EN300 328/ EN301 893/ EN301 489-1/-17
ARIB STD-33/T66/T71 (Japan)
EMI: FCC
Part
15
* Please check Moxa
’
s website for the most up-to-date certification status.
Warranty
5 years
Details: See http://
www.moxa.com/warranty
ATTENTION
The AWK-4121 is NOT a portable mobile device and should be located at least 20cm away from
the human body.
1-4