![Moxa Technologies AWK-4121 Скачать руководство пользователя страница 50](http://html1.mh-extra.com/html/moxa-technologies/awk-4121/awk-4121_user-manual_1842389050.webp)
AirWorks AWK-4121 User’s Manual
Web Console Configuration
Mail server (SMTP)
Setting
Description
Factory Default
IP address
The IP address of your email server. None
User name & Password
Setting
Description
Factory Default
User name and password used in the
SMTP server
None
From e-mail address
Setting
Description
Factory Default
Max. 63 characters
Enter the administrator’s e-mail
address which will be shown in the
“From” field of a warning e-mail.
None
To E-mail address 1/ 2/ 3/ 4
Setting
Description
Factory Default
Max. 63 characters
Enter the receivers’ e-mail addresses. None
Relay
The AWK-4121 has one relay output, which consists of 2 terminal block contacts on the
AWK-4121’s top panel. These relay contacts are used to indicate user-configured events and
system failure.
The two wires attached to the relay contacts form an open circuit when a user-configured event is
triggered. If a user-configured event does not occur, the relay circuit will remain closed. For safety
reasons, the relay circuit is kept open when the AWK-4121 is not powered.
Relay Event Types
You can check the box for
Active
to enable the event items. All default values are deactivated
(unchecked). Details for each event item can be found in the “System log Event Types” table on
page 3-31.
3-34