This product is intended to be supplied by a Listed Power Unit 
marked “Class 2” or “LPS” and rated O/P: 12 to 48 VDC, minimum 
6 W (12 V to 48V), 25°C. 

 

 

 

ATTENTION 

Make sure the external power adapter (includes power cords and 
plug assemblies) provided with the unit is certified and suitable 
for use in your country. 

 

 

 

ATTENTION 

Do not use the PoE Injector. Instead, please use an IEEE802.3af 
or IEEE802.3at compliant PSE (Power Sourcing Equipment) for 
PoE (Power over Ethernet) device. 

 

Grounding the Moxa AWK-3131A-M12-RCC 

Grounding and wire routing help limit the effects of noise due to 
electromagnetic interference (EMI). Run the ground connection from the 
ground screw to the grounding surface prior to connecting devices. 

 

ATTENTION 

This product is intended to be mounted to a well-grounded 
mounting surface, such as a metal panel. 

 

Connecting the Power Input 

Pinouts for the Power Inputs and Relay Output 

Pin 

Name 

Usage 

V1+ 

DC Power Input 1 

V1- 

V2+ 

DC Power Input 2 

V2- 

 

Relay Output 


I1 

Digital Input 

COM_1 

Digital Input GND 

I2 

Digital Input 

10 

COM_2 

Digital Input GND 

 

 

 

Содержание Airworks AWK-3131A-M12-RCC

Страница 1: ...rt Moxa Americas Toll free 1 888 669 2872 Tel 1 714 528 6777 Fax 1 714 528 6778 Moxa China Shanghai office Toll free 800 820 5036 Tel 86 21 5258 9955 Fax 86 21 5258 5505 Moxa Europe Tel 49 89 3 70 03 99 0 Fax 49 89 3 70 03 99 99 Moxa Asia Pacific Tel 886 2 8919 1230 Fax 886 2 8919 1231 Moxa India Tel 91 80 4172 9088 Fax 91 80 4132 1045 2019 Moxa Inc All rights reserved ...

Страница 2: ...tems is missing or damaged please contact your customer service representative for assistance NOTE Antennas are not included and should be purchased separately The AWK is certified with 2 dBi omni directional antennas with QMA to RP SMA adapters Installation and Configuration Before installing the AWK 3131A M12 RCC make sure that all items in the Package Checklist are in the box In addition you wi...

Страница 3: ...omepage opens you will need to enter the user name and password For first time configuration enter the default user name and password and then click on the Login button Username admin Password moxa ATTENTION For security reasons we strongly recommend changing the password To do so select Maintenance Password and then follow the on screen instructions Step 5 Select the operation mode for the AWK 31...

Страница 4: ...I0 and DI1 3 Reset button 4 A antenna connector 5 B antenna connector 6 System LEDs PWR1 PWR2 PoE FAULT and STATE 7 Signal strength indicator 8 CLIENT WLAN and LAN LEDs 9 RS 232 console port 10 M12 LAN Port 10 100 1000BaseT X 11 Model name 12 Screw holes for wall mounting kit 13 DIN rail mounting kit ...

Страница 5: ...o reattach the DIN rail attachment plate to the AWK 3131A M12 RCC make sure the stiff metal spring is situated towards the top as shown in the figures below STEP 1 Insert the top of the DIN rail into the slot just below the stiff metal spring STEP 2 The DIN rail attachment unit will snap into place as shown below To remove the AWK 3131A M12 RCC from the DIN rail simply reverse Steps 1 and 2 ...

Страница 6: ...ce with wall mount plates attached as a guide to mark the correct locations of the 4 screws The heads of the screws should be less than 6 0 mm in diameter and the shafts should be less than 3 5 mm in diameter as shown in the figure at the right Do not screw the screws in all the way leave a space of about 2 mm to allow room for sliding the wall mount panel between the wall and the screws NOTE Test...

Страница 7: ...ment Wiring Requirements WARNING Safety First Be sure to disconnect the power cord before installing and or wiring your Moxa AWK 3131A M12 RCC WARNING Safety First Calculate the maximum possible current in each power wire and common wire Observe all electrical codes dictating the maximum current allowed for each wire size If the current goes above the maximum ratings the wiring could overheat caus...

Страница 8: ...ipment for PoE Power over Ethernet device Grounding the Moxa AWK 3131A M12 RCC Grounding and wire routing help limit the effects of noise due to electromagnetic interference EMI Run the ground connection from the ground screw to the grounding surface prior to connecting devices ATTENTION This product is intended to be mounted to a well grounded mounting surface such as a metal panel Connecting the...

Страница 9: ...to the DC power inputs make sure the DC power source voltage is stable Wiring the Relay Contact The AWK 3131A M12 RCC has one relay output which consists of the two contacts of the terminal block on the AWK 3131A M12 RCC s top panel The two wires attached to the Relay contacts form an open circuit when a user configured event such as the network connection status change DI0 1 status change or powe...

Страница 10: ...0 1000BaseT X Ethernet port 8 pin shielded M12 connector with A coding The 10 100 1000TX port located on the AWK 3131A M12 RCC front panel is used to connect to Ethernet enabled devices Most users configure this port for Auto MDI MDI X mode in which case the port s pinouts are adjusted automatically depending on the type of Ethernet cable used straight through or cross over and the type of device ...

Страница 11: ...power isolator is used both being compliant with the EN 50155 standard Reset Button The RESET button is located on the top panel of the AWK 3131A RCC You can reboot the AWK 3131A M12 RCC or reset it to factory default settings by pressing the RESET button with a pointed object such as an unfolded paper clip System reboot Hold the RESET button down for under 5 seconds and then release Reset to fact...

Страница 12: ...mode or ACC Slave mode with connection established Off AP Master Sniffer ACC Master mode or connection is NOT established in ACC Slave mode WLAN Amber Amber On WLAN is in AP Master mode WLAN is in Client Slave ACC Master ACC Slave mode with connection established Amber blinking Traffic in AP Client Master Slave ACC mode Off WLAN is in Sniffer mode WLAN is in Client Slave ACC Master ACC Slave mode ...

Страница 13: ...annels DFS Dynamic Frequency Selection channel support In AP mode when a radar signal is detected the device will automatically switch to another channel However according to regulations after switching channels a 60 second availability check period is required before starting the service Security SSID broadcast enable disable Firewall for MAC IP Protocol Port based filtering 64 bit and 128 bit WE...

Страница 14: ...5dBm MCS11 40 MHz Typ 20 1 5dBm MCS12 40 MHz Typ 19 1 5dBm MCS13 40 MHz Typ 18 1 5dBm MCS14 40 MHz Typ 17 1 5dBm MCS15 40 MHz 802 11a Typ 23 1 5 dBm 6 to 24 Mbps Typ 21 1 5 dBm 36 Mbps Typ 20 1 5 dBm 48 Mbps Typ 18 5 dBm 54 Mbps 802 11n 5 GHz Typ 23 1 5dBm MCS0 20 MHz Typ 20 1 5dBm MCS1 20 MHz Typ 20 1 5dBm MCS2 20 MHz Typ 20 1 5dBm MCS3 20 MHz Typ 19 1 5dBm MCS4 20 MHz Typ 18 1 5dBm MCS5 20 MHz T...

Страница 15: ...dBm 36 Mbps 78 dBm 48 Mbps 74 dBm 54 Mbps 802 11n 2 4 GHz 89 dBm MCS0 20 MHz 85 dBm MCS1 20 MHz 85 dBm MCS2 20 MHz 82 dBm MCS3 20 MHz 78 dBm MCS4 20 MHz 74 dBm MCS5 20 MHz 72 dBm MCS6 20 MHz 70 dBm MCS7 20 MHz 95 dBm MCS8 20 MHz 90 dBm MCS9 20 MHz 87 dBm MCS10 20 MHz 83 dBm MCS11 20 MHz 80 dBm MCS12 20 MHz 74 dBm MCS13 20 MHz 71 dBm MCS14 20 MHz 69 dBm MCS15 20 MHz 87 dBm MCS0 40 MHz 83 dBm MCS1 4...

Страница 16: ... 20 MHz 71 dBm MCS15 20 MHz 84 dBm MCS0 40 MHz 81 dBm MCS1 40 MHz 77 dBm MCS2 40 MHz 75 dBm MCS3 40 MHz 71 dBm MCS4 40 MHz 67 dBm MCS5 40 MHz 64 dBm MCS6 40 MHz 63 dBm MCS7 40 MHz 90 dBm MCS8 40 MHz 85 dBm MCS9 40 MHz 82 dBm MCS10 40 MHz 81 dBm MCS11 40 MHz 77 dBm MCS12 40 MHz 73 dBm MCS13 40 MHz 71 dBm MCS14 40 MHz 68 dBm MCS15 40 MHz Protocol Support General Protocols Proxy ARP DNS HTTP HTTPS IP...

Страница 17: ...nsing Power Requirements Input Voltage 12 to 48 VDC redundant dual DC power inputs or 48 VDC Power over Ethernet IEEE 802 3af compliant Input Current 12 V 0 67 A 12 VDC to 0 17 A 48 VDC 25 C Connector 10 pin removable terminal block Power Consumption 12 to 48 VDC 670 mA Reverse Polarity Protection Present Standards and Certifications Safety EN 60950 1 LVD UL 60950 1 IEC 60950 1 CB EMC EN 55032 24 ...

Страница 18: ... The AWK 3131A M12 RCC is NOT designed for the general public To deploy AWK 3131A M12 RCCs and establish a wireless network safely a well trained technician is required for installation ATTENTION Use the antennas correctly The 2 4 GHz antennas are needed when the AWK 3131A M12 RCC operates in IEEE 802 11b g n The 5 GHz antennas are needed for IEEE 802 11a n Make sure your antenna installation is w...

Отзывы: