- 8 -
ATTENTION
This product is intended to be supplied by a UL-listed power
adapter suitable for use at a Thermomechanical Analysis (TMA) of
75 degree Celsius, which output meets SELV circuit and LPS
standards; output rated 9 - 30Vdc, 1.3A min. or 24Vdc, 0.49A
min.
ATTENTION
Make sure the external power adapter (includes power cords and
plug assemblies) provided with the unit is certified and suitable
for use in your country.
Grounding the Moxa AWK-1137C
Grounding and wire routing help limit the effects of noise due to
electromagnetic interference (EMI). Run the ground connection from the
ground screw to the grounding surface prior to connecting devices.
ATTENTION
This product is intended to be mounted to a well-grounded
mounting surface, such as a metal panel. There must be no
electrical potential difference between any two grounding points;
otherwise, there is a risk that the device could be destroyed.
Installing Cable Extended Antennas for Outdoor Applications
If the antenna or the AWK device is installed outdoors or in an open-air
setting, proper lightning protection is required to prevent direct lightning
strikes on the AWK device. In order to prevent coupling currents from
nearby lightning strikes, a lightning arrester should be installed as part of
your antenna system. Ground the device, antenna, as well as the arrester
properly to provide maximum outdoor protection for the device.