2/21
NT 1001-C00 11.08 C24 i - C36 i e
ECCENTRIC PISTON PUMP
MOUVEX PRINCIPLE
SAFETY INSTRUCTIONS, STORAGE, INSTALLATION AND MAINTENANCE
C24 i - C36 i MODELS
Pump N° :
Commissioning date :
TECHNICAL CHARACTERISTICS
- Maximum pump speed :
460 rpm
- Maximum running temperature :
•
PTFE L seals
. . . . . . . . . . . . . . . . . . . . . . . . . . 80°C
•
other seals :
* continuous . . . . . . . . . . . . . . . . . . . . . . . . . .100°C
* washing/rinsing/sterilisation . . . . . . . . . . . . .121°C
- Maximum suction pressure :
• In normal use, the suction pressure must be higher than the
required NPSH and
less than 2 bar
(29 psi).
• During
CIP/SIP
of the pump, the suction pressure must not
exceed
3 bar
(43,5 psi).
• Pump
stopped
, the pressure must not exceed
6 bar
(87 psi).
- Maximum differential pressure :
• C24 i . . . . . . .9 bar (130,5 psi)*
• C36 i . . . . . . .6 bar (87 psi)*
- Cylinder capacity :
• C24 i . . . . . . .0,946 litre
• C36 i . . . . . . .1,420 litre
- Informations about PTFE L seals :
• This seal is composed of fibreglass.
•
CAUTION : This seal does not accept thermal shock
and Clean In Place.
* When the pump works with an inlet pressure less than zero, the maximum
outlet pressure will be calculated as if the inlet pressure is equal to zero.
1. OVERALL DIMENSIONS . . . . . . . . . . . . . . . . . . . . . . . . . .3
2. INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
2.1 Orientation of the pump ports . . . . . . . . . . . . . . . . . . . .7
2.2 Direction of rotation . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
2.3 Protection of the pump installation . . . . . . . . . . . . . . . .7
2.4 Hoisting devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
2.5 Unit Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
3. UTILISATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
3.1 Noise level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
3.2 Commissioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
3.3 Dry running . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
3.4 Pump stop . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
4. CLEAN IN PLACE (CIP) & STERILISATION IN
PLACE (SIP) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
4.1 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
4.2 CIP circuit recommended . . . . . . . . . . . . . . . . . . . . . .11
4.3 Pumps arranged in series . . . . . . . . . . . . . . . . . . . . . .11
4.4 Pumps arranged in parallel . . . . . . . . . . . . . . . . . . . . .12
4.5 Successive cycles . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
4.6 Sterilisation In Place (SIP) . . . . . . . . . . . . . . . . . . . . .13
5. MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
5.1 Necessary tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
6. OPENING OF THE PUMP . . . . . . . . . . . . . . . . . . . . . . . .14
6.1 Assembly / Dismantling . . . . . . . . . . . . . . . . . . . . . . . .14
6.2 Checking of parts . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
7. ASSEMBLY OF CYLINDER/PISTON . . . . . . . . . . . . . . . .16
8. PROTECTION OF THE BELLOWS . . . . . . . . . . . . . . . . . .17
9. CHANGING THE LIP SEAL . . . . . . . . . . . . . . . . . . . . . . .18
10. CHANGING THE ORIENTATION OF THE PORTS . . . . .19
10.1 Discharge port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
10.2 Suction port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
11. DRAINING OF BEARING . . . . . . . . . . . . . . . . . . . . . . . .20
12. OPTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21
12.1 Liquid detector . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21
12.2 Bellows monitoring system . . . . . . . . . . . . . . . . . . . .21
SUMMARY
Page
This is a SAFETY ALERT SYMBOL
When you see this symbol on the product, or in the manual, look
for one of the following signal words and be alert to the potential for
personal injury, death or major property damage.
Warns of hazards that WILL cause serious personal injury,
death or major property damage
Warns of hazards that CAN cause serious personal injury,
death or major property damage.
Warns of hazards that CAN cause personal injury or property
damage.
NOTICE
Indicates special instructions which are very important and
must be followed.
SAFETY INFORMATIONS
WARNING
CAUTION
DANGER