G O / N O G O S I G N A L
The TorqueLab
â
is equipped with visual (green and red LED) and audible (buzzer) signals to
provide the user instant torque status during operation. These signals operate in conjunction
with the transducer’s capacity and tolerance settings.
Torque
Range Signal
Status
____________________________________________________________________________
Buzzer
Long
Beep
No Go
On
Go
Off
High Tol. Icon
On
High
Capacity
Low
Tol.
Icon
Off
Buzzer
Short
Beep
No
Go
Flashing
Go
Off
High
Tol.
Icon
Flashing
High
Tolerance
Low
Tol.
Icon
Off
Buzzer
Short
Beep
No
Go
Off
Go
On
High Tol. Icon
Off
Low
Tolerance
Low
Tol.
Icon
Off
Buzzer
Off
No Go
Flashing
Go
Off
High Tol. Icon
Off
Low
Capacity
Low
Tol.
Icon
Flashing
Buzzer
Off
No
Go
On
Go
Off
High Tol. Icon
Off
Low Tol. Icon
On
Zero
N/A
N/A