background image

BF-Series (Mini Electric Screwdrivers BF035 & BF045) Operation Instructions

Corporate Headquarters: 

1080 North 11th Street, San Jose, CA 95112    Phone: (408) 292-2214   Fax: (408) 292-2733

www.mountztorque.com

Page 5

Features

- Over Heat Protection (OHP) and Over Current Protection (OCP) protect 

driver from damage or malfunction.

- Temperature Detection powers down the unit and resets automatically when 

unit restores to acceptable levels.

- Switchable 110V & 230V input voltage. Unit will reset itself if motor/current 

overload is too high.

- Start & Stop Signal Output (for PLC).

- Screwdriver Lock Signal Input (for PLC).

- Unit can be connected to the Scout (Screw Counter).

Model: STC40
Item # 145754
Specifications:
Rated Output: 2.6A 105W
Max. Output: 10A
Output VDC: 30/40V
Input VAC: 110/230V
Size inches (W x D x H): 4 3/8” x 7 1/2” x 2 3/8”
Weight: 1.8 lbs.
Operates with: BF-Series and NF-Series

STC40 transformer is power supply designed for operating the BF-Series & NF-
Series brushless electric screwdrivers. Only use this transformer when operating
any BF-Series & NF-Series models.

STC40 Transformer

FT-30D Mini Transformer 

The FT-30D Mini Transformer is power supply designed for operating
only the Mini BF-Series brushless electric screwdrivers. 

Features

- Over Heat Protection (OHP) and Over Current 

Protection (OCP) protect driver from damage or malfunction.

- Temperature Detection powers down the unit and resets 

automatically when unit restores to acceptable levels.

- Switching power supply 110V - 230V input voltage. Unit will 

reset itself if motor/current overload is too high.

- Unit can be connected to the Scout (Screw Counter).

Model: FT-30D
Item # 145870
Specifications:
Rated Output: 1.2A
Output VDC: 30V
Input VAC: 110 ~ 230V
Size inches (W x D x H): 2 3/4” x 5 1/8” x 1 1/2”
Weight: 8.8 oz.
Operates only: BF035 & BF045

Program Lock Key - 

Item # 145774

The Program Lock Key protects from incidental or operator tampering of the 
programmable settings on the side of select BF-Series models* (V3 models only).
To adjust the settings the Program Lock Key must be is plugged into the STC40 or
FT-30D Mini Transformer. 

* Note! The Program Key is required for the BF-Series Mini models, Standard
Models and Soft Stop Models. RPM & Soft Start Settings cannot be adjusted 
without it.

The Program Key 

cannot

be used with BF-Series Standard Plus Models, Soft Stop Plus Models & Angle & Auto Reverse

Models.

Содержание BF035

Страница 1: ...lectric Screwdrivers BF035 BF045 Operation Instructions Corporate Headquarters 1080 North 11th Street San Jose CA 95112 Phone 408 292 2214 Fax 408 292 2733 www mountztorque com Page 1 Rev 1 12 15 11 for V3 Models Only ...

Страница 2: ...mage or malfunction Features a LED display that signals the tool status for the operator to view Can be connected with the Scout Screw Counter External torque adjustment scale Requires transformer power supply All models are ESD designed and prevent the occurrence of electrostatic discharge which improves production yields manufacturing costs product quality product reliability reputation and prof...

Страница 3: ... notch on the socket Tighten knurled ground ring 4 Select a bit Retract the bit collar Insert the bit and release the retracted collar To avoid damaging fasteners make sure the proper bit is suitable for the head of the fastener 5 The torque limit is determined by the tension of the coil spring housed in the torque adjustment nut The tighter the coil spring is wound the higher the torque limit is ...

Страница 4: ...et speed 2 Select Reverse of F R switch for increasing speed Or select Forward of F R switch for decreasing speed 3 Press Speed button and select the target speed The set speed can be recognized by the colors of the LEDs 4 Keep pressing the Lock button for 2 second to go back to operating work mode Program Lock Key The Program Lock Key protects from incidental or operator tampering of the programm...

Страница 5: ...T 30D Mini Transformer The FT 30D Mini Transformer is power supply designed for operating only the Mini BF Series brushless electric screwdrivers Features Over Heat Protection OHP and Over Current Protection OCP protect driver from damage or malfunction Temperature Detection powers down the unit and resets automatically when unit restores to acceptable levels Switching power supply 110V 230V input...

Страница 6: ...ere they are needed most right on the assembly area The Scout is designed to detect cross threading omissions unfinished rundowns and cycle complete The screw counter takes the control of the assembly process out of the operator s hands Item 145790 Screw presenters are small tabletop devices used to organize and automate work areas and produc tion cells Screw presenters make assemblers and the ass...

Страница 7: ...ne the approximate torque setting Refer to the charts to determine the reference number setting for your torque requirement How to Read the Torque Charts Torque ranges lbf in approximate tightening torque Figures below each chart indicate scale setting on the tool Some drivers have more than one spring Select the appropriate spring to achieve the desired torque setting BF035 1 2 3 4 5 6 Torque Sca...

Страница 8: ...ervice Mountz Inc features an experienced calibration and repair staff Our trained technicians can calibrate and repair most any tool Mountz provides rapid service with quality that you can trust as we offer three state of the art cali bration lab and repair facilities that can calibrate up to 20 000 lbf ft With over 45 years of experience Mountz s in depth knowledge of torque is reflected in our ...

Отзывы: