Double Hit Mode

The Double Hit mode is for very soft joint applications. When an electric screwdriver runs down a fastener and the tool clutches off once
the preset torque is achieved there can be some joint relaxation that can occur. The Double Hit mode has the electric screwdriver perform
a second hit to stabilize the torque for joint relaxation.

Joint relaxation is caused by the surface of part(s) embedding or by "soft parts" such as gaskets, plastics or spongy material, which 
collapses under the clamping force created in a torque condition. For Hard Joint applications there is no need to use the 
Double Hit mode.

Press the "sT" button continuously until the power light turns 

Red

The clutch of the electric driver works twice at the set torque under the "Double Hit" mode. The Double Hit will increase the repeatability 
accuracy at the target torque by double checking.

Note!

The STC 30 Plus models that are designed with Double Hit Mode and Soft Start mode features are not functional with any BF-
Series electric screwdrivers. The Double Hit Mode and Soft Start mode features are built-in to the “Plus” models of the BF-
Series electric screwdrivers.

STC30 Plus (v4.1) Transformer

(Rev 1.0 8/8/08)

Corporate Headquarters: 

1080 North 11th Street, San Jose, CA 95112    Phone: (408) 292-2214   Fax: (408) 292-2733

www.etorque.com

Page 3

OCP (Over Current Protection)

The power will shut down automatically when the current exceeds 12 - 13A. The controller should be reset by turning off the power switch
for one minute and turned back on. If the current is not over the limit, power will turn on.

There is another OCP in a secondary circuit. The power will be disappear for 5 seconds when the current is over 4A over 3 seconds or
when current is over 6A over 0.5 seconds. The transformer recovers automatically. The transformer gives an alarm signal by blinking Green
and Orange color on the LED lights along with beep buzzer sound.

Description

Primary OCP

Secondary OCP

Detection

Limit current

Time duration

12 ~ 13A

immediately

Condition A

Condition B

4A

6A

3 sec.

0.5 sec.

Protection

Whole power shuts
down permanently

Output power disappears for 5 sec.

Protection
Signal

LED

Buzzer

no

no

blinking 

Green    Orange

Off

blinking 

Orange        Off

Normal frequent

beep On/Off

Higher Frequent

beep On/Off

Recovery

Turn off the power switch
and on after 1 minute

Auto recovery after 5 sec.

Over Heat Protection

The thermistor will shut down whole power supply if the unit over heats. The controller should be reset by turning off the power switch for
one minute and turned back on. If the current is not over the limit, power will turn on.

Ratcheting Clutch Alarm

An alarm and break system notifies you when the ratcheting clutch occurs with an electric screwdriver. If the tool ratchets continuously 5 or
6 times, the STC-30 Plus will provide a buzzer alarm along with the red LED light Also it will stop the output power for 5 seconds as a 
secondary protection.

Содержание 145683

Страница 1: ...Plus v4 1 Operation Instructions Corporate Headquarters 1080 North 11th Street San Jose CA 95112 Phone 408 292 2214 Fax 408 292 2733 www etorque com RoHS Power Supply for Electric Screwdrivers Rev 1 0...

Страница 2: ...river The driver will automatically stop when the preset torque has been reached Soft Start Mode Press the sT button in the lower bottom right The power light will blink once and turn Yellow which ind...

Страница 3: ...l shut down automatically when the current exceeds 12 13A The controller should be reset by turning off the power switch for one minute and turned back on If the current is not over the limit power wi...

Страница 4: ...8 White Brown Not Used RJ 11 Modular Jack 2M 1 5M Corporate Headquarters 1080 North 11th Street San Jose CA 95112 Phone 408 292 2214 Fax 408 292 2733 www etorque com Page 4 1 5 4 3 2 1 Motor 2 Limit...

Страница 5: ...Blue stripe Green stripe PLC connections Electric Screwdriver STC30 Plus Scout Screw Counter PLC PLC Signal Out Cycle End NG OK Buzzer Signal In Cycle Start Driver Lock Signal In Driver Lock Signal Ou...

Страница 6: ...ce Converter STC 30 Plus Accessory The PLC interface converter provides three types of signals by converting the open collector signal from STC 30 Plus Model U 3 Item 145619 Size WxDxH 3 x 2 3 8 x 3 4...

Страница 7: ...nction 2 1 Buzzer does not stop sound when the power is on There are two possible problem One is the micro processor IC The other is the SB21 sub board Push the sT button soft start button If the colo...

Страница 8: ...ing is not same 20 30 38V as the set position EF with Low K with Low K with High check and replace the voltage selector switch slide switch The High Low switch should be also checked 6 Screwdriver kee...

Страница 9: ...e of failure please test the component with multi tester as below Page 9 Step 01 Step 02 With the failure of Q33 and Q31 the following components are commonly damaged too Check the following process T...

Страница 10: ...ers 1080 North 11th Street San Jose CA 95112 Phone 408 292 2214 Fax 408 292 2733 www etorque com Damaged Fuse make Open by short circuit test Damaged Thermistor make Open by short circuit test Rectifi...

Отзывы: