background image

STC30 Plus (v4.1) Transformer

(Rev 1.0 8/8/08)

Corporate Headquarters: 

1080 North 11th Street, San Jose, CA 95112    Phone: (408) 292-2214   Fax: (408) 292-2733

www.etorque.com

Trouble Shooting 

5. Screwdriver RPM
The rotation speed of the screwdriver is not same as the selected one. Test the voltage between pin #1 and 5. If the reading is not same 20
/30/ 38V as the set position EF with Low/ K with Low/ K with High, check and replace the voltage selector switch (slide switch). The
High/Low switch should be also checked.

6. Screwdriver keeps running when power is on

6-1. Problem is with the screwdriver side.

6-2. Check and replace the FET Q33

7. Screwdriver does not stop at the target torque immediately and it rachets several times before stopping.
The Q31 must be damaged. Check and replace Q31 component.

8. Power shut down. Continuous fuse blown

Page 8

Содержание 145683

Страница 1: ...Plus v4 1 Operation Instructions Corporate Headquarters 1080 North 11th Street San Jose CA 95112 Phone 408 292 2214 Fax 408 292 2733 www etorque com RoHS Power Supply for Electric Screwdrivers Rev 1 0...

Страница 2: ...river The driver will automatically stop when the preset torque has been reached Soft Start Mode Press the sT button in the lower bottom right The power light will blink once and turn Yellow which ind...

Страница 3: ...l shut down automatically when the current exceeds 12 13A The controller should be reset by turning off the power switch for one minute and turned back on If the current is not over the limit power wi...

Страница 4: ...8 White Brown Not Used RJ 11 Modular Jack 2M 1 5M Corporate Headquarters 1080 North 11th Street San Jose CA 95112 Phone 408 292 2214 Fax 408 292 2733 www etorque com Page 4 1 5 4 3 2 1 Motor 2 Limit...

Страница 5: ...Blue stripe Green stripe PLC connections Electric Screwdriver STC30 Plus Scout Screw Counter PLC PLC Signal Out Cycle End NG OK Buzzer Signal In Cycle Start Driver Lock Signal In Driver Lock Signal Ou...

Страница 6: ...ce Converter STC 30 Plus Accessory The PLC interface converter provides three types of signals by converting the open collector signal from STC 30 Plus Model U 3 Item 145619 Size WxDxH 3 x 2 3 8 x 3 4...

Страница 7: ...nction 2 1 Buzzer does not stop sound when the power is on There are two possible problem One is the micro processor IC The other is the SB21 sub board Push the sT button soft start button If the colo...

Страница 8: ...ing is not same 20 30 38V as the set position EF with Low K with Low K with High check and replace the voltage selector switch slide switch The High Low switch should be also checked 6 Screwdriver kee...

Страница 9: ...e of failure please test the component with multi tester as below Page 9 Step 01 Step 02 With the failure of Q33 and Q31 the following components are commonly damaged too Check the following process T...

Страница 10: ...ers 1080 North 11th Street San Jose CA 95112 Phone 408 292 2214 Fax 408 292 2733 www etorque com Damaged Fuse make Open by short circuit test Damaged Thermistor make Open by short circuit test Rectifi...

Отзывы: