Ix350_02b_oi_e.doc / Mai-18
Page 32 / 50
Continuation „Serial Menu“:
SERIAL PROTOCOL
Determines the sequence of characters send, when using the serial output for cyclic data transmission under time
control (xxxxxxx = value SERIAL VALUE).
Setting „1“ removes the unit address from the string which allows a slight faster transmission cycle.
0
Transmission report = Unit No., +/-, data, LF, CR
1
1
+/-
X
X
X
X
X
X
X
LF
CR
1
Transmission report = +/-, data, LF, CR
+/-
X
X
X
X
X
X
X
LF
CR
SERIAL TIMER (S)
This register determines the cycle time in seconds for cycling transmission of
SERIAL VALUE when using the serial
output. (On a serial request, the cycling transmission is stopped for 20 s)
0,000
All cyclic transmission is switched off. The unit will send data upon a serial request or with
command SERIAL PRINT.
…
60,000
Cycle time in seconds.
SERIAL VALUE
This parameter defines the value to be transmitted.
Setting
Code
Register contents
0
:0
Measurement Result
1
:1
SSI Data
2
:2
SSI Single
3
:3
SSI Rev
4
:4
SSI Dir Result
5
:5
SSI Mask Result
6
:6
Minimal Value
7
:7
Maximal Value
8
:8
SSI Set Result
9
:9
SSI Data