Ix350_02b_oi_e.doc / Mai-18
Page 27 / 50
Continuation „Preselection 1 Menu“:
START UP DELAY 1 (S)
Start-up suppression for the switching condition of preselection 1. Time to start the monitoring function.
This adjustment is only valid for the switching condition |RESULT|<=|PRES| or RESULT<=PRES and mode SPPED
and PROCESS TIME.
(Start Up Delay 3 and 4 have an automatic start up suppression).
0.000
No start-up suppression
…
60.000
Start-up suppression in seconds
EVENT COLOR 1
Event-depending change of the display color for the switching condition of preselection 1.
EVENT COLOR 1 has the lowest priority. EVENT COLOR 2 … 4 are allowed to overwrite this color change.
0 NO CHANGE
No color change.
1 CHANGE TO RED
Color change to red
2 CHANGE TO GREEN
Color change to green
3 CHANGE TO YELLOW Color change to yellow