FM26001c_e.doc / Nov-11
Page 19 / 27
Serial -Menu
(Configuration of the serial link)
Code Setting Range Default
Serial Protocol
Determines the sequence of characters sent, when you use the serial
output for cyclic data transmission under timer control
(xxxxxxx is the measuring value transmitted).
„F3“
0 ... 1
0
0=
Transmission = Unit Nr. – Data, LF, CR
1=
Transmission = Data, LF, CR
Setting "1" removes the unit address from the string which allows a
slightly faster transmission cycle.
Unit No.
0:
1 1
+/- X X X X X X LF CR
1:
+/- X X X X X X LF CR
Serial Timer
T
his register determines the cycle time in seconds for cyclic transmission
when the Printer Mode is switched on.
Range 0.001 to 9.999 seconds.
With setting “0” all cyclic transmission is switched off and the unit will
only send data upon request (PC mode)
„F4“
0 ... 9.99
0
Register Code
Serial access code of the register which, in Printer Mode, should be
transmitted with every cycle.
„F5“
0 ... 19
(:0) … (;9)
8
6.2.7.
Phase Trimming
Trim Settings
Range
Default
Trim Time:
Time base (sec.) for adding or subtracting additional impulses to the output
frequency (differential frequency = 1/ Trim Time.
(see also chapter 7.)
0,000 … 1,000
0,100