DZ27001a_e.doc / Jan-13
Page 30 / 36
The table below shows the setup procedure for an application according to the previous
example. Parameters which are not mentioned are optional, but not relevant for this function.
Nr,
Menu
Parameter
Value Function
1
Preselect Menu Preselection1
Preselection2
Preselection3
---
100
300
unimportant (relay 1 is used for standstill)
Switching point for "underspeed"
Switching point for "overspeed"
2
Command
Menu
Key Enter Func.
Input 1 Config.
Input 1 Func.
=7
=1
=7
ENTER key to release the relay 3 catch
Function of "Control1" input is static HIGH
"Control1" input to release the relay 3 catch
3
Switching
Menu
Pulse Time 1
Pulse Time 2
Pulse Time 3
Presel. Mode1
Presel. Mode2
Presel. Mode3
Output Polarity
Start-up Mode
Start-up Relay
Lock Relay
Standstill Time
=0
=0.30
=0
=3
=1
=4
=0
=0
=0
=4
=1.00
Relay 1 static
Relay 2 timed output 0.3 seconds
Relay 3 static
Relay 1 energizes after lapse of standstill time
Relay 2 energizes when absolute value underpassed
Relay 3 energizes with positive overstepping only
All relays with non-inverted function (energize)
No start-up-delay function
No relay assignment to start-up-delay
Relay 3 to operate with catch function
Standstill output 1 second after detection of
"frequency = 0"
(i.e. 6 seconds after the last input pulse)
4
Display Menu
Display Mode
Encoder Factor
Multiplier
=3
=32
=1
Engineering units are RPM
Tooth wheel generates 32 pulses per revolution
No specific impulse scaling