21
5 ON
Obstacle detection with motor at limit
switch;
with motor not running (door closed,
open or after a total stop command), hin-
ders any movement if the safety devices
(e.g. photoelectric cells) detect an obsta-
cle;
6 ON
“Maintained Action”, door operation
while keeping the pushbutton pressed
excludes the remote control function;
7 OFF
Re-opening during closure;
insert
the photoelectric cells (see safety devices);
when detecting an obstacle during the
gate-closure phase, the photoelectric cells
cause the direction to reverse until full
opening (if the device used, set the dip
switch to ON);
Opening
Closure
8 OFF
Partial stop (only with connected
photoelectric cells, otherwise leave the dip
set to ON).
If an obstacle is detected during movement,
the gate stops.
NB: with the automatic closing function on
(dip switch 1 ON), the gate closes
automatically
ref. c)
, or use the transmitter
or the pushbutton
9 -
Dip switch not used, leave it “OFF”;
10 ON
Photoelectric cell test;
at every gate
opening and closure command, the con-
trol unit checks the efficiency of the photo-
electric cells (
see page 19
).
a)
b)
a)
b)
c)
12
6
3
9
1
2
4
5
7
8
10
11
1"
120"