2. Set the test pressure by using the
scroll buttons ( ) to
adjust pressure. The test pressure
should be the same or less than the
operating pressure of the system
being tested.
1. Select smoke test by pressing
“select” ( ) button while
smoke test icon is highlighted in red.
[email protected] www.motorvac.com
8
Smoke Test:
The purpose of a smoke test is to fill a system with pressurized smoke until the set pressure is
reached. Use the high intensity Phazer White light to detect the smoke exiting any leak points. The
Phazer White light has a focusing feature to zoom in on the leak points and improve visibility.
3. Follow on screen instructions and
press the ( ) button to start
pressurizing the system.
4. The screen displays the set pressure
as well as the current output pressure.
The test will automatically stop after
10 minutes.