O p e r a t i o n
5 - 1 1
SG 20 00 Ins tal la tion and O pera tion M anua l
Tables 5-1 and 5-2 provide additional information on the user-related features and output levels of
the SG2-LR:
T a b l e 5 - 1
SG 2 - L R f e a t u r e s
Feature Desc ription
Optical power test point
This test point enables monitoring of the optical power level
at the input to the module. The nominal scale factor is
1.0 V/mW.
Hybrid current test point
This test point enables monitoring the current drawn by the
amplifier section of the integrated optical receiver hybrid. The
nominal scale factor is 1.0 V/A. The hybrid current test-point
voltage is between 0.150 V and 0.350 V (hybrid current of
150 mA through 350 mA) when the module is enabled under
normal operating conditions.
Receiver enable
A green LED that provides visual indication of the receiver’s
enable status.
Fault indicator
A red LED that illuminates when the module is enabled but
the hybrid current is outside the normal operating range.
Optical power status
A green LED that is ON (
NORM
) when the optical power is
within the recommended operating range (refer to Table A-4).
Two red LEDs indicate that the optical power is above (
HIGH
)
or below (
LOW
) the recommended optical input power range.
T a b l e 5 - 2
SG 2 - L R m i n i m u m o u t p u t l e v e l s
O p t i c a l i n p u t
l e v e l ( d B m / m W )
T P V o l t s
( 1 m W = 1 V )
O u t p u t ( d B m V )
7 7 c h a n n e l s
O u t p u t ( d B m V )
1 1 0 c h a n n e l s
C o m m e n t s
3.2/2.1
2.1
32
30
Low level alarm
3.0/2.0
2.0
31
30
Low level alarm
2.8/1.9
1.9
31
29
Low level alarm
2.6/1.8
1.8
30
29
Low level alarm
2.3/1.7
1.7
30
28
Low level alarm
2.0/1.6
1.6 29
28
Normal
1.8/1.5
1.5 29
27
Normal
1.5/1.4
1.4 28
26
Normal
1.0/1.3
1.3 27
25
Normal
0.8/1.2
1.2 27
25
Normal
0.5/1.1
1.1 26
24
Normal
0.0/1.0
1.0
25 23
Optimum
–0.5/0.9
0.9 24
22
Normal
–1.0/0.8
0.8 23
21
Normal
–1.5/0.7
0.7 22
20
Normal