S p e c i f i c a t i o n s
A - 7
SG 20 00 Ins tal la tion and O pera tion M anua l
Table A-13 lists the current requirements for various options and the two platforms available in the
SG 2000:
T a b l e A- 1 3
C u r r e n t r e q u i r e m e n t s
Option Watts
ac
pow er
Am p s
@90V
Am p s
@60V
Am p s
@52V
Am p s
@44V
Basic- platform (one-way,
single receiver: Note 1)
Silicon
Module
D,
F
Module C, E, G
Module
B
82.48
69.36
56.24
1.22
1.03
0.83
1.83
1.54
1.25
2.11
1.78
1.44
2.50
2.10
1.70
Gallium
Arsenide
(GaAs)
Module
D,
F
Module C, E, G
Module
B
92.72
77.04
61.36
1.37
1.14
0.91
2.06
1.71
1.36
2.38
1.98
1.57
2.81
2.33
1.86
Add for:
Additional
receiver-split
band
8.96 0.13
0.20
0.23
0.27
Additional
receiver,
redundant
0.64 0.01
0.01
0.02
0.02
Analog
return
transmitters
9.84 0.15
0.22
0.25
0.30
Digital
return
transmitters
DS-SG2-DRT/A
DS-SG2-DRT-2X/A
4.17
8.33
0.08
0.17
0.12
0.23
0.12
0.25
0.14
0.27
Reduction for split return
(3.52) (0.05)
(0.08)
(0.09)
(0.11)
Each
ingress
switch
1.96 0.03
0.04
0.05
0.06
ADU
2.24 0.03
0.05
0.06
0.07
MCB
1.81 0.03
0.04
0.05
0.05
Status
monitor
3.41 0.05
0.08
0.09
0.10
Note 1: Module letters denote the following:
Module B - two bridger level outputs
Module C - Three bridger level outputs
Module D - Four bridger level outputs
Module E - One trunk level, two bridger level outputs
Module F - Two trunk level, two bridger level outputs
Module G - Two trunk level, one bridger level output
Содержание Starline SG 2000