49
increments, not in the usual 16. This allows more pre-
cise setting of rated audio, etc. Press HOME to move
the cursor back and forth between the frequency and
signalling type. The first digit will flash to indicate which
type is currently selected. Press Mode to scroll through
the available selections.
When in receive mode, reception of a properly mod-
ulated signal at the proper frequency is indicated by the
radio as follows:
BUSY LIGHT FLASHES - Proper RF frequency
being received with proper signalling types.
BUSY LIGHT STAYS ON - Proper RF frequency
being received.
To check for proper demodulation, apply an RF car-
rier at 1000 microvolts, modulated with the signal
frequency and deviation level indicated in Table 19.
The table also shows which integrated circuit is tested
by the various signalling types.
NOTE
For trunked models, make sure the microphone is
removed from the grounded hangup clip so that the
radio busy light is extinguished before you apply the
signal.
When in transmit mode, DTMF modulation pro-
duces a sidetone in the speaker. All signalling types will
continually modulate the transmitted signal for detec-
tion/measurement by external instruments.
Refer to ALIGNMENT VIA IBM PERSONAL COM-
PUTER paragraph VIII. of this manual for instructions on
adjustment of Touch Code encoder microphone DTMF
modulation level.
To exit the test mode, press Mode and scroll to the
"EXIT” display that follows the last frequency and/or sig-
nalling type. Press HOME to exit and return to the "TST
FREQ” display.
X. CONTROL HEAD TESTING
The control head test mode is part of the diagnos-
tics built into the radio and is entered through the front
panel programming sequence. (See FRONT PANEL
PROGRAMMING AND ADJUSTMENTS of this manual,
and specifically, paragraph XVI. for password entry.)
This test mode allows you to perform button and
display tests to verify proper operation.
Display
Modulation
Demodulation
Type
1.
CS
None
None
Carrier Squelch, HearClear Disabled
2.
PL
100Hz
100Hz
PL
3.
PC
11Hz
None
PL (Compensation Adjust)
4.
PD
67Hz
None
PL (Deviation Adjust)
5.
DL
100Hz
100Hz
DPL
6.
LS
100Hz
100Hz
Trunked Low-Speed
7.
M6
1500Hz
1500Hz
MDC–600
8.
MC
1500Hz
1500Hz
MDC–1200
9.
HS
1500Hz
1500Hz
Trunked High-Speed
10.
DF
1477 & 941Hz
None
DTMF Digit #
11.
HC
None
None
Carrier Squelch, HearClear Enabled
Table 18. Signalling Types
NOTES:
1.
HearClear always disabled during test mode except on “HC” signalling type.
2.
Adaptive splatter feature always disabled.
3.
Sine waves used for trunked, MDC, and DPL signalling modulation/demodulation rather than actu-
al data signalling.
4.
Volume level is 256 steps versus normal 16 to aid in setting rated audio level.
5.
Transmitter time-out timer is disabled.
6.
Microphone audio is disabled during MDC, DTMF, and trunked high-speed modulation.
7.
Synthesizer always in narrowband configuration during transmit.
8.
“Normal” radio operation is disabled (i.e., cannot initiate or receive calls, edit operator selectable
scan list, etc.)
9.
For trunked radios, place the microphone in the hangup clip (grounded) while in the “TEST FRE-
QUENCY” menu to unsquelch the radio and allow receiver measurements to be made.
Signalling Modulation
Deviation
IC
Type
Frequency
Level
Tested
Trunking High-Speed
1500Hz
690Hz
Signalling Filter (SFIC)
Trunking Low-Speed
100Hz
250Hz
Signalling Filter (SFIC)
MDC–600/MDC–1200
1500Hz
880Hz
Signalling Filter (SFIC)
PL/DPL
100Hz
250Hz
Audio Filter (AFIC)
Table 19. Checking Modulation Frequency and Deviation
Содержание Spectra
Страница 6: ...v PERFORMANCE SPECIFICATIONS FOR SPECTRA PRIVACY PLUS TRUNKED CONVENTIONAL 900 MHz RADIO ...
Страница 7: ...vi PERFORMANCE SPECIFICATIONS FOR SPECTRA SMARTNET TRUNKED CONVENTIONAL 900 MHz RADIO ...
Страница 8: ...vii PERFORMANCE SPECIFICATIONS FOR SPECTRA 9000 RADIOS 900 MHz 30 WATTS ...
Страница 25: ...1 GENERAL INFORMATION 1 ...
Страница 73: ...53 INSERT GPW 7221 B Figure 22 Front Panel Diagnostics Key Closure Displays ...
Страница 75: ...INSERT GXW 4278 O PICKUP FROM PW 4320 O 55 CONTROL STATION WIRING DIAGRAM ...
Страница 79: ...PUSHBUTTON SPECTRA 900 MHz RADIO MECHANICAL EXPLODED VIEW 59 INSERT GXW 6225 B ...
Страница 96: ...82 MECHANICAL EXPLODED VIEW PARTS LIST FOR SPECTRA 900 MHz RADIO ...