background image

 

 

PTP 300/500 Series 

Deployment Guide 

 

 

Contents 

 

Protect Your Installation .............................................................................................................................. 2

 

Checklist, Site Survey and Tools................................................................................................................. 5

 

Bench Testing (Optional)............................................................................................................................. 6

 

Mast, Tower or Building Installation .......................................................................................................... 10

 

Installation Wiring ...................................................................................................................................... 13

 

Cable Preparation and Installation ............................................................................................................ 14

 

Testing and Fault Finding (Troubleshooting)............................................................................................. 17

 

Installation and Commissioning................................................................................................................. 20

 

User Information to be Recorded .............................................................................................................. 23

 

Registration Warranty and Ordering Information....................................................................................... 25

 

License Keys and Regulatory Information................................................................................................. 26

 

 

 

4Gon   www.4Gon.co.uk   [email protected]   Tel: +44 (0)1245 808195   Fax: +44 (0)1245 808299 

Содержание PTP 500

Страница 1: ...nstallation 10 Installation Wiring 13 Cable Preparation and Installation 14 Testing and Fault Finding Troubleshooting 17 Installation and Commissioning 20 User Information to be Recorded 23 Registration Warranty and Ordering Information 25 License Keys and Regulatory Information 26 4Gon www 4Gon co uk info 4gon co uk Tel 44 0 1245 808195 Fax 44 0 1245 808299 ...

Страница 2: ...is already cross bonded to the mast or tower the same cross bonding points on the mast or tower must be used for the CAT 5e cable We recommend that the practices and procedures detailed in the Motorola manual R56 STANDARDS AND GUIDELINES FOR COMMUNICATION SITES 68P81089E50 be applied to all new site build activities This manual is provided on the PTP 300 or PTP 500 CD ROM Lightning Protection Unit...

Страница 3: ...educes the possibility of a direct strike Mount the ODU in this zone Zone A Zone A Recommended NOT Recommended Zone B Zone B Zone A Finial Recommended Zone B The following protection requirements are mandatory The ODU must be earthed Screened CAT 5e cable must be used Surge arrestor of type PTP LPU must be installed at building entry There must be an earth connection at building entry More informa...

Страница 4: ...nna cables should be grounded within 0 3 metres 1 foot of the ODU and Antennas Additional Grounding Requirements for Connectorized ODU Note Antenna cables grounded using an Andrew grounding assembly type 223158 or similar NOTE Refer to instructions contained in the Andrew grounding kit for correct installation or if instructions are missing refer to http awapps commscope com catalog product_detail...

Страница 5: ...ents Link planning enables a link of known quality to be installed This involves the acquisition of path profile data using Motorola s free LINKPlanner utility The LINKPlanner predicts data rates and reliability over the path It allows the user to try different antenna heights and RF power settings When the link is installed the mean path loss can be checked to confirm that the predicted data rate...

Страница 6: ...cense key For the purpose of these tests normal off the shelf Ethernet cables can be used Power Checks Step 1 Connect the RJ45 at one end of a cable to the ODU Step 2 Undo the retaining screw of the PIDU Plus and hinge back the cover Step 3 Plug in the ODU to PIDU Plus Cable ensuring that it snaps home Step 4 Put the cover back and tighten the screw Step 5 Plug in power lead using a cable appropri...

Страница 7: ...54 1 x where 2 x 254 Connect the LAN cable to the PC shown here in yellow NOTE If this IP address is not recognised try 10 10 10 11 Master and 10 10 10 10 Slave Some units may have been pre configured with these IP addresses If it is necessary to use IP addresses 10 10 10 11 and 10 10 10 10 ensure that the PC is configured with an IP address of 10 10 10 n where n is any value between 2 and 254 but...

Страница 8: ...ting Change Password Step 2 If an upgrade to the software is required select Software Upgrade and follow the on screen instruction Latest software is available from our web site http motorola motowi4solutions com software ptp Step 3 Check the License Key information and ensure you are using the correct Region Code Otherwise select License Key and replace with the alternative key supplied and reboo...

Страница 9: ...ation configuration and reboot Paired Unit Repeat the Power Checks and Configuration Checks for the paired unit and check that the status of the link shows UP on the Status Page More information PTP 300 Series User Guide or PTP 500 Series User Guide Section System Administration Pages 4Gon www 4Gon co uk info 4gon co uk Tel 44 0 1245 808195 Fax 44 0 1245 808299 ...

Страница 10: ...length The lanyard must be made from a material that does not degrade in an outdoor environment WARNING The safety lanyard must be fixed to a separate fixing point that is not part of the direct mounting system for the ODU WARNING If the safety loop or its fixing is damaged in any way or has been exposed to a shock loading due to a fall replace it with a new one before undertaking any further oper...

Страница 11: ... mount the ODU on poles with diameter less than 50mm 2 or greater than 75mm 3 The ODU mounting bracket is designed to work only with poles with diameter in the 50 mm 2 to 75 mm 3 range Do not over tighten the bolts The ODU must be mounted using the following steps ensuring that the cable entry is at the bottom Step 1 Attach the bracket strap to the pole using M8 x 70 mm bolts M8 flat washers and M...

Страница 12: ... lead large tag M10 to the tower metal work On no account must this be attached to the mounting bracket bolts More information PTP 300 Series User Guide or PTP 500 Series User Guide Section Mounting the ODUs WARNING A cable measuring card must NEVER be used at the ODU end connected to power from the PIDU It must only be used at the bottom of the mast with a multimeter This is because the PIDU volt...

Страница 13: ...13 Installation Wiring More information PTP 300 Series User Guide or PTP 500 Series User Guide Section Lightning Protection 4Gon www 4Gon co uk info 4gon co uk Tel 44 0 1245 808195 Fax 44 0 1245 808299 ...

Страница 14: ...ype Superior Essex BBDGE CAT 5e Connector Type Tyco AMP 5 569278 Crimp Tool Tyco AMP 2 231652 Die set1 853400 0 Gland Motorola WB 1811 Connector load bar Trim to5mm start with tails over length to assist insertion into load bar 15mm 15mm 40mm Nom Connector Housing 8 Brown 7 Light Brown 6 Green 5 Light Blue 4 Blue 3 Light Green 2 Orange 1 Light Orange Note Fit Gland to cable before fitting RJ45 Sol...

Страница 15: ... ODU Step 2 Support the drop cable and gently hand screw the gland body into the ODU until the O ring seal is flush to the ODU body Caution Do not fit the back shell prior to securing the gland body Step 3 Once the gland is fully hand screwed into the ODU it may be tightened to a torque of 7 ftlbs 10Nm with a 22mm wrench 4Gon www 4Gon co uk info 4gon co uk Tel 44 0 1245 808195 Fax 44 0 1245 808299...

Страница 16: ...t the ODU or PTP LPU this can be achieved by removing the gland back shell first Then wiggle the cable to release the tension of the gland body as shown in the figure below Then you can unscrew the gland body and depress the RJ45 locking tab with a small screwdriver Apply small movements to the cable until you see a gap here before unscrewing the gland body More information PTP 300 Series User Gui...

Страница 17: ... LAN port of the PIDU to the network The yellow Ethernet LED should blink randomly as traffic passes through If the Power and Ethernet LEDs do not illuminate correctly test the link end as described in this flowchart references such as 1 are to the tests on the following pages Start Is the green power LED on solid Is the power LED flashing Did the Ethernet LED flash 10 times Is Ethernet activity n...

Страница 18: ...n wiring or a corrupt ODU software load 6 Connection is not 1000 BaseT If the Ethernet connection to the network is only 10 100 BaseT when 1000 BaseT is expected check that the wiring to pins 4 5 and 7 8 is correct For example the wiring to pins 4 and 7 may be crossed 7 Test RJ45 Resistance If the above tests fail to diagnose the issue there may be a fault in the wiring of the RJ45 cable that conn...

Страница 19: ...istance between pins 4 7 ohms 0 0 8 1 0 1 6 10 2 7 2 7 3 3 20 4 6 4 4 5 0 30 6 5 6 1 6 7 40 8 3 7 8 8 4 50 10 2 9 5 10 1 60 12 1 11 2 11 8 70 14 0 12 9 13 5 80 15 8 14 6 15 2 90 17 7 16 3 16 9 100 19 6 18 0 18 6 150 29 0 26 5 27 1 200 38 4 35 0 35 6 250 47 7 43 5 44 1 300 57 1 52 0 52 6 More information PTP 300 Series User Guide or PTP 500 Series User Guide Section Troubleshooting Fault Finding 4G...

Страница 20: ...refers to that of the peer unit being installed In each of the states detailed above the unit should be aligned to give the highest pitch tone It should be noted that if when in the Synchronized or Registered state the tone varies wildly you may be suffering from interference or a fast fading link Installing in this situation may not give a reliable link The cause of the problem should be investig...

Страница 21: ...t typically takes less than 60 seconds to determine the length of the link being installed The Master unit will remain in the Scanning state until the range of the link has been established The Master unit will only move to the Synchronized state when the range of the link has been established Retrying same channel If at the end of the ranging period the Registered state is not achieved due to int...

Страница 22: ... TO DISARM BOTH UNITS in the link This is necessary in order to Turn off the audible alignment aid Enable Adaptive Modulation Clear unwanted installation information from the various systems statistics Store the link range for fast link acquisition on link drop Items for Future Reference Take note of the following items for future reference Save a copy of the configuration using the Save and Resto...

Страница 23: ...r to identify future changes in the installation Table 2 Resistance Values Measure Resistance Between Pins Measured Resistance Value LOCAL Measured Resistance Value REMOTE 1 2 3 6 4 5 7 8 1 3 4 7 1 8 1 ODU Ground 8 ODU Ground Table 3 Link Identification LOCAL REMOTE IP Address Link Name MAC Address 4Gon www 4Gon co uk info 4gon co uk Tel 44 0 1245 808195 Fax 44 0 1245 808299 ...

Страница 24: ...24 User Information to be Recorded User Notes 4Gon www 4Gon co uk info 4gon co uk Tel 44 0 1245 808195 Fax 44 0 1245 808299 ...

Страница 25: ...al shorts building fires vandalism Dropped Units Component or manufacturing defects With our warranties you have peace of mind knowing that your investment is fully protected and if you are covered with the Advanced Replacement Warranty your communications will be back in operation in the shortest time possible Register Your Units to receive updates and activate your warranty Upon receipt of your ...

Страница 26: ...26 License Keys and Regulatory Information 4Gon www 4Gon co uk info 4gon co uk Tel 44 0 1245 808195 Fax 44 0 1245 808299 ...

Отзывы: