PMP 400/430 and PTP 200/230 Series
Motorola PMP Solutions User Guide Supplement
Issue 6.0 May 2011
Page 51 of 77
Figure 29: Configured Region Code on SM Configuration => General page
Figure 30: Active Region Code on SM Home => General Status page
The AP or BHM always operates under its manually configured Region Code (the one on the
Configuration => General page), and so does not show a Region Code on its Home => General
Status page.
Under normal operations, APs and BHMs operating with DFS (see
Table 14
) will experience an
additional minute after power-up or reboot before they will register any SMs or BHSs. SMs and
BHSs operating with DFS (see
Table 14
) will experience an additional minute after they reboot
before they will register to an AP or BHM.
It takes two reboots to set the parameters described below on a module starting from factory
defaults. Set the
Region
Code
as described above,
Save Changes
, and
Reboot
. If the module