![Motorola OM 1000 Скачать руководство пользователя страница 78](http://html.mh-extra.com/html/motorola/om-1000/om-1000_installation-and-operation-manual_245370078.webp)
Appendix B
Cabling Specifications
This appendix provides interface-cabling guidelines for the OM 1000.
RS-232 DB9 Interface Cabling (
PORT
2
)
The OM 1000 is configured as a DTE:
Connector
type
DB9 male shielded connector with screw locks
Cable type
Shielded twisted pair
Baud rate
Port 1: 9,600 bps asynchronous (fixed), 8/N/1
Port 2: 19.2K maximum asynchronous (no sync mode), 8/N/1; Port 2 supports 300, 600,
1,200, 2,400, 9,600, and 19,200 bps
Table B-1
RS-232 DB9 Interface Connector Pinout
P i n N u m b e r
S i g n a l
D i r e c t i o n
D e s c r i p t io n
1
RLSD (DCD)
In
Receive Line Signal Detector (Data Carrier
Detect)
2
RX In
Receive
data
3
TX Out
Transmit
data
4
DTR Out
Data
Terminal
Ready
5
SG (Shield)
Signal Ground (Shield)
6
DSR
In
Data Set Ready
7
RTS
Out
Request To Send
8
CTS
In
Clear To Send
9
RI In
Ring
Indicator
DB25 RS-232 Interface Cabling (
PORT
4
and
PORT
5
- Optional Module)
The OM 1000 is configured as a DTE.
Connector type
DB25 male shielded connector with screw locks
Cable type
25 conductor shielded
Bit rate
56 K maximum (sync or async)
Async: 300, 600, 1,200, 2,400, 4,800, 9,600, 19,200, 38,400, or 57,600 bps
Sync: 300 through 57,600 bps
OM 1000 Installation and Operation Manual