Installation Guide
7
•
Provide a sufficient number of power drops for your equipment.
•
Ensure adequate, dust-free ventilation to all installed equipment.
•
Identify and prepare Ethernet and console port connections.
•
Verify that cable lengths are within the maximum allowable distances for optimal signal transmission.
•
Verify that the device is powered through an
Uninterruptible Power Supply
(UPS).
1.5 Selecting a Site
Switch units can be mounted in a standard 19 inch equipment rack or on a flat surface. Be sure to follow the
guidelines listed below when choosing a site:
•
Locate the switch unit at the center of all devices you want to link and near a power outlet.
•
Maintain a tempurature range within -40
°
to 149
°
F / 40
°
to 65
°
C and humidity range within 10% to 90%
non-condensing.
•
Provide adequate space (approximately 2 inches) on all sides for proper air flow.
•
Confirm access for installing, cabling, and maintaining all devices.
•
Install the switch unit so that status LEDs are clearly visible.
•
Ensure that twisted-pair cables are always routed away from power lines, fluorescent lighting fixtures,
and other sources of electrical interference, such as radios and transmitters.
•
Ensure that the unit is connected to a separate grounded power outlet that provides 100 to 250VAC and
50 to 60Hz power levels.
•
Ensure that the unit is within 6.6 ft / 2m of each device that is powered from an independent circuit
breaker.
•
Use of a filter or circuit breaker is recommended.