3-12
Computer Group Literature Center Web Site
MOTLoad Firmware
3
Default VME Settings
As shipped from the factory, the MVME6100 has the following VME
configuration programmed via Global Environment Variables (GEVs) for
the Tsi148 VME controller. The firmware allows certain VME settings to
be changed in order for the user to customize the environment. The
following is a description of the default VME settings that are changeable
by the user. For more information, refer to the MOTLoad User’s Manual
and Tundra’s Tsi148 User Manual, listed in
Appendix C, Related
Documentation
.
❏
MVME6100>
vmeCfg –s –m
Displaying the selected Default VME Setting
- interpreted as follows:
VME PCI Master Enable [Y/N] = Y
MVME6100>
The PCI Master is enabled.
❏
MVME6100>
vmeCfg –s –r234
Displaying the selected Default VME Setting
- interpreted as follows:
VMEbus Master Control Register = 00000003
MVME6100>
The VMEbus Master Control Register is set to the default
(RESET) condition.
❏
MVME6100>
vmeCfg –s –r238
Displaying the selected Default VME Setting
- interpreted as follows:
VMEbus Control Register = 00000008
MVME6100>
The VMEbus Control Register is set to a Global Timeout of 2048
µ
seconds.
❏
MVME6100>
vmeCfg –s –r414
Displaying the selected Default VME Setting
- interpreted as follows:
CRG Attribute Register = 00000000
CRG Base Address Upper Register = 00000000