Solving Startup Problems
http://www.motorola.com/computer/literature
B-3
B
IV. Continued
2. At the command line prompt, type in:
env;d <CR>
This sets up the default parameters for the debugger
environment.
3. When prompted to Update Non-Volatile RAM, type in:
y <CR>
4. When prompted to Reset Local System, type in:
y <CR>
5. After the clock speed is displayed, immediately (within
five seconds) press the Return key:
<CR>
or
BREAK
to exit to the System Menu. Then enter a 3 for “Go to
System Debugger” and Return:
3 <CR>
Now the prompt should be:
162-Diag>
6. You may need to use the cnfg command (see your board
Debugger Manual) to change clock speed and/or Ethernet
Address, and then later return to:
env <CR>
and step 3.
7. Run the selftests by typing in:
st <CR>
The tests take as long as 10 minutes, depending on RAM
size. They are complete when the prompt returns. (The
onboard self-test is a valuable tool in isolating defects.)
8. The system may indicate that it has passed all the self-
tests. Or, it may indicate a test that failed. If neither
happens, enter:
de <CR>
Any errors should now be displayed. If there are any
errors, go to step VI. If there are no errors, go to step V.
V. The debugger is
in system mode
and the board
autoboots, or the
board has passed
self-tests.
A. No apparent
problems —
troubleshooting is
done.
No further troubleshooting steps are required.
Table B-1. Troubleshooting MVME162P2 Boards
Condition
Possible Problem
Try This:
Содержание MVME162P-242
Страница 1: ...MVME162P2 VME Embedded Controller Installation and Use V162P2A IH2 Edition of November 2000 ...
Страница 12: ...xii ...
Страница 14: ...xiv ...
Страница 46: ...1 28 Computer Group Literature Center Web Site Hardware Preparation and Installation 1 ...
Страница 118: ...C 2 Computer Group Literature Center Web Site Network Controller Data C ...
Страница 124: ...D 6 Computer Group Literature Center Web Site Disk Tape Controller Data D ...