![Motorola MTM800 FuG ET Скачать руководство пользователя страница 41](http://html.mh-extra.com/html/motorola/mtm800-fug-et/mtm800-fug-et_basic-service-manual_244729041.webp)
Test Setup & Testing for 380–430 MHz
5.1 - 3
Receiver Tests
1. Simulate Base Station (registration)
2. RSSI Test
Transmitter Tests
1. Power Profile
2. Power Burst (Control Range)
3. Tx Burst Timing Error
4. Tx Frequency Error
5. Vector Error RMS, Peak and Residual
4.
Transmitter Tests
RF Gen Level
Range 1
Test Group 1
-90dBm
Burst Power
35 – 40dBm
Timing Error
<=0.25 Symbols
Frequency
Error
-/+ 100 Hz
Vector Error
Max 10% RMS,
Max 30% Peak,
Max 5% Residual
5.
Call Processing
Talk Back
1 kHz Test Signal
Group Mode
Range 1
Test Group 1
-90dBm
6.
Call Processing
Call to Mobile
Private Mode
Private Call
Private Mode
RF Gen Level Burst
Power
-90dBm
35 – 40dBm
Timing Error
<=0.25 Symbols
Frequency Error
-/+ 100 Hz
Vector Error
Max 10% RMS,
Max 30% Peak,
Max 5% Residual
7.
Digital Duplex
Test (Tx)
RF Gen Level
Private Mode
-50dBm
Burst Power
10 – 22dBm
Timing Error
<=0.25 Symbols
Frequency
Error
-/+ 100 Hz
Vector Error
Max 10% RMS,
Max 30% Peak,
Max 5% Residual
Table 5.1-2
Test Setup (Continued)
No.
Test Name
Test Setup
Terminal Setup
Test Conditions
Limits
Содержание MTM800 FuG ET
Страница 2: ......
Страница 6: ...vi COPYRIGHT Notes ...
Страница 8: ...viii DOCUMENT HISTORY Notes ...
Страница 16: ...xvi Product Safety and RF Exposure Notes ...
Страница 32: ...2 8 Model Information Accessories Notes ...
Страница 36: ...4 2 Programming the Terminal Notes ...
Страница 38: ...5 2 Test Setup Testing Notes ...
Страница 56: ...5 1 18 Test Setup Testing for 380 430 MHz Notes ...
Страница 116: ...A 10 Replacement Parts Kits Notes ...
Страница 119: ......