Part Numbers
The following information is provided as a reference for the parts associated with
V9 telephones.
9. Vibrator feature not functioning.
Transceiver board assembly
defective.
Replace the transceiver board assembly (refer
to 1c). Verify that the fault has been cleared and
reassemble the unit with the new transceiver
board assembly.
10. Internal Charger not working.
Faulty charger circuit on transceiver
board assembly.
Test a selection of batteries in the rear pocket of
the desktop charger. Check LED display for the
charging indications. If these are charging
properly, then the internal charger is at fault.
Replace the transceiver board assembly (refer
to 1c). Verify that the fault has been cleared and
reassemble the unit with the new transceiver
board assembly.
11. Real Time Clock resetting when
standard battery is removed.
Lithium button cell in the display
board may be depleted.
Refer service to a Level 3 service center for
replacement.
Table 3. Level 1 and 2 Troubleshooting Chart (Continued)
SYMPTOM
PROBABLE CAUSE
VERIFICATION AND REMEDY