Base Station Installation
In fixed station installation, an AC power supply is used instead of the
12 V battery. (It is possible to connect a backup battery to the battery
terminals on the power supply.) One power supply model is available:
–
F2369 for 220 V AC, 50 Hz, field programmable for 110 VAC, 60 Hz.
Figure 2: Power Supply
This power supply also serves as a charger for the external backup
12-V battery, if connected. When AC power failure occurs, the battery
functions as the main power source. When AC power is again available,
the power supply charges the battery.
The cable and connector supplied with the power supply enable
connecting the supply directly to DC connector J4 at the radio rear
panel. (The DC Power Cable supplied with the radio is not used in this
installation.)