Maintenance & Troubleshooting
7 - 9
Four Slot Spare Battery Charger
Battery is not
recharging.
Mobile computer
removed from the
cradle too soon.
Replace the mobile computer into the cradle. It can take up to
four hours to recharge a completely depleted battery pack if
mobile computer is suspended or longer if the mobile computer
is on.
For Windows Mobile 5.0 devices, view battery status by tapping
Start
>
Settings
>
System
tab >
Power
icon.
For Windows CE 5.0 devices, view battery status by tapping
Start
>
Settings
>
Control Panel
>
Power
icon.
Battery is faulty.
Verify that other batteries charge properly. If so, replace the
faulty battery.
Mobile computer is
not inserted correctly
into the cradle.
Remove the mobile computer and reinsert it correctly. Verify
charging is active.
For Windows Mobile 5.0 devices, view battery status by tapping
Start
>
Settings
>
System
tab >
Power
icon.
For Windows CE 5.0 devices, view battery status by tapping
Start
>
Settings
>
Control Panel
>
Power
icon.
Warning Message - “!
Unable to obtain a
server assigned IP
address. Try again
later or enter an IP
address in Network
Settings.”
This message occurs
if a suspend/resume
cycle is performed
and the mobile
computer radio is not
associated (e.g. due
to being out of range)
Tap
OK
to close the message. The mobile computer will obtain
address information and communicate through the Ethernet
cradle.
Table 7-5
Troubleshooting The Four Slot Spare Battery Charger
Symptom
Possible Cause
Solution
Batteries not
charging.
Battery was removed
from the charger or
charger was unplugged
from AC power too
soon.
Ensure MSR is receiving power. Ensure mobile computer is
attached correctly. Confirm main battery is charging. If a mobile
computer battery is fully depleted, it can take up to four hours to
fully recharge a battery (if the mobile computer is off and longer if
the mobile computer is operating).
For Windows Mobile 5.0 devices, view battery status by tapping
Start
>
Settings
>
System
tab >
Power
icon.
For Windows CE 5.0 devices, view battery status by tapping
Start
>
Settings
>
Control Panel
>
Power
icon.
Battery is faulty.
Verify that other batteries charge properly. If so, replace the faulty
battery.
Battery contacts not
connected to charger.
Verify that the battery is seated in the battery well correctly with the
contacts facing down.
Table 7-4
Troubleshooting the Four Slot Ethernet Cradle (Continued)
Symptom
Cause
Solution
Содержание MC9090G - RFID - Win Mobile 5.0 624 MHz
Страница 1: ...MC909X Mobile Computer User Guide ...
Страница 2: ......
Страница 3: ...MC909X User Guide 72E 72215 04 Rev A March 2007 ...
Страница 6: ......
Страница 14: ...xii MC909X User Guide ...
Страница 22: ...xii MC909X User Guide ...
Страница 100: ...2 56 MC909X User Guide ...
Страница 152: ...4 22 MC909X User Guide ...
Страница 178: ...5 26 MC909X User Guide ...
Страница 200: ...6 22 MC909X User Guide ...
Страница 226: ...B 4 MC909X User Guide ...
Страница 248: ...Index 6 MC909X User Guide ...
Страница 250: ......
Страница 251: ......
Страница 252: ...Motorola Inc One Symbol Plaza Holtsville New York 11742 1300 http www symbol com 72E 72215 04 Revision A March 2007 ...