7 - 38 MC70 Integrator Guide
User Already Logged In
If already logged into the EDA, the user can launch the login dialog box for the following reasons:
•
Connect to and re-enable a cancelled profile. To do this:
•
Launch the Log On/Off dialog.
•
Select the cancelled profile from the profile list.
•
Login to the profile.
•
Log off the EDA to prevent another user from accessing the current users network privileges.
•
Switch EDA users to quickly logoff the EDA and allow another user to log into the EDA.
No User Logged In
If no user is logged into the EDA, launch the login dialog box and log in to access user profiles.
The
Login
dialog box varies if it is:
•
Launched by WCS, because the service is connecting to a new profile that needs credentials.
•
Launched by WCS, because the service is trying to verify the credentials due to credential caching rules.
•
Launched by a user, when a user is logged in.
•
Launched by a user, when no user is logged in.
NOTE
Re-enable cancelled profiles using the Profile Editor Wizard and choosing to connect to the cancelled
profile. Cancelled profiles are also re-enabled when a new user logs on.
Table 7-28
Log On/Off Options
Field
Description
Wireless Profile Field
When launching the login application, the Wireless Profile field has available all
the wireless profiles that require credentials. This includes profiles that use EAP
TLS, PEAP, LEAP, and EAP-TTLS.
Profile Status Icon
The profile status icon (next to the profile name) shows one of the following
states:
The selected profile is cancelled.
The selected profile is enabled but is not the current profile.
The profile is the current profile (always the case for WCS Launched).
Network Username and
Password Fields
The Network Username and Network Password fields are used as credentials
for the profile selected in the Wireless Profile field. Currently these fields are
limited to 159 characters.
Mask Password
Checkbox
The
Mask Password
checkbox determines whether the password field is
masked (i.e., displays only the '*' character) or unmasked (i.e., displays the
entered text). Check the box to unmask the password. Uncheck the box to mask
the password (the default).
Status Field
The status field displays status that is important to the login dialog. If the user
opens the dialog and needs to prompt for credentials for a particular profile at
this time, it can use the status field to let the user know that the network is held
up by the password dialog being open.
Содержание MC70 - Enterprise Digital Assistant
Страница 1: ...Integrator Guide MC70 Enterprise Digital Assistant ...
Страница 2: ......
Страница 3: ...MC70 Integrator Guide 72E 71768 02 Revision A March 2007 ...
Страница 6: ...iv MC70 Integrator Guide ...
Страница 12: ...xii MC70 Integrator Guide Appendix B Software Configuration Radio Power Status LED B 1 Index ...
Страница 30: ...1 12 MC70 Integrator Guide ...
Страница 60: ...2 30 MC70 Integrator Guide ...
Страница 108: ...5 18 MC70 Integrator Guide ...
Страница 164: ...7 40 MC70 Integrator Guide ...
Страница 184: ...A 8 MC70 Integrator Guide ...
Страница 186: ...B 2 MC70 Integrator Guide ...
Страница 198: ...Glossary 12 MC70 Integrator Guide ...
Страница 206: ......
Страница 207: ......
Страница 208: ...Motorola Inc One Symbol Plaza Holtsville New York 11742 1300 http www symbol com 72E 71768 02 Revision A March 2007 ...