background image

 

 

FlexPass OFR100                                                             

 

K02000-000                               - 8 -                               06/29/01 

 

11. FCC REGISTRATION INFORMATION

 

 

FCC REQUIREMENTS PART 15 

Caution:

 Any changes or modifications in construction of this device which are not expressly approved by the 

manufacturer for compliance could void the user's authority to operate the equipment. 

 
NOTE: This device complies with 

Part 15 of the FCC Rules

 

Operation is subject to the following two conditions: 

1. This device may not cause harmful interface, and 
2. This device must accept any interference received, including interference that may cause undesired operation. 
 
This equipment has been tested and found to comply with the limits for a 

Class B Digital Device

, pursuant to 

Part 15 of 

the FCC Rules

. These limits are designed to this equipment generates, uses, and can radiate radio frequency energy and, if 

not installed and used in accordance with the instructions, may cause harmful interference to radio communications. 
However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause 
harmful interference to radio or television reception, which can be determined by turning the radio or television off and on, 
the user is encouraged to try to correct interference by one or more of the following measures. 
 
1. Reorient or relocate the receiving antenna. 
2. Increase the separation between the equipment and receiver. 
3. Connect the equipment into an outlet on another circuit. 
4. Consult the dealer or an experienced radio/TV technician for help. 

 

12. Warranty and Service

 

FlexPass OFR100 warranty is 3 years from the shipped date; returns must have an RMA (Return 
Material Authorization) number. The customer is to provide a description of the specific problem. The 
customer is to include serial numbers, formats, and model numbers with the items to be returned. If the 
exact duplicated of returned cards or tags are requested, the customer must provide Motorola with exact 
format and ID numbers needed. 
 

Contact Technical Support 
Motorola 
3041 Orchard Parkway 
San Jose, CA 95134-2017 
Tel (408) 383-4000, Main 
Tel (800) 646-3252, Technical Support 
Fax (408) 434-7057 

 

NOTE

:  Damage occurring during shipment is deemed the responsibility of the carrier, and claims should be made directly 

  

to the carrier. 

Содержание FlexPass OFR100

Страница 1: ...FlexPass OFR100 K02000 000 1 06 29 01 OPERATING AND INSTALLATION MANUAL FlexPass OFR100 Open Format Reader ...

Страница 2: ...ions 3 2 Product Description 3 3 Features 4 4 Identifying Supplied Parts 4 5 Specification 4 6 Installation 5 7 Wire Color Coded Wiring 6 8 Wire Connection to A Host Controller 6 9 Wire Connection to SDC1000 7 10 Operation 7 11 FCC Registration Information 8 12 Warranty and Service 8 ...

Страница 3: ...ugh the cabinet slots as they may touch voltage points or short out parts that could result in fire or electric shock Never spill liquid of any kind on the product 7 To reduce the risk of electric shock do not disassemble this product by yourself but take it to qualified service whenever service or repair is required 8 Unplug this product from the Direct Current DC power source and refer to qualif...

Страница 4: ...tor Easy Mounting to a single gang box 4 Identifying supplied parts Please unpack and check the contents of the box Reader Module OFR100 Bezel Manual 1 ea 1 ea 1 ea 5 Specification Read Range Time Up to 4 10cm 300ms with Motorola FlexPass ASC 121T card and minimum read range 3 7 5cm Input Voltage Current DC 5V 12V 120mA at standby max 150mA Output Format 26 bit Wiegand or ABA Track II Magstripe Ex...

Страница 5: ... top hole If you have installed an electric gang box then skip this step and go to step 6 2 6 2 Put reader cable into the center hole and install the reader module by using two 6 32 or M3 screws Not included 6 3 Put bezel on to the reader module then push bezel until you hear the locking sound 6 4 To detach the bezel hold both sides of the bezel push the bezel to the bottom and pull the bezel forw...

Страница 6: ...re Power Ground VDC GND Black wire INPUT Beeper control Beeper Blue wire LED control LED Brown wire OUTPUT Wiegand Format Wiegand Data 0 Data 0 Green wire Wiegand Data 1 Data 1 White wire OUTPUT ABA Track II Format ABA Card Present CP Orange wire ABA Clock CLK White wire ABA Data Data Green wire 8 Wire Connection to a Host Controller ...

Страница 7: ...LED will change color to Red again for the next reading 10 3 LED Control To change the LED colors you may connect the LED Control Input Brown wire to ground and the Green LED will turn on indicating that the reader is in standby mode Present proximity card and the LED will change color to Red then Green again for the next reading 10 4 Beeper Control In normal operation the reader generates one bee...

Страница 8: ...his equipment does cause harmful interference to radio or television reception which can be determined by turning the radio or television off and on the user is encouraged to try to correct interference by one or more of the following measures 1 Reorient or relocate the receiving antenna 2 Increase the separation between the equipment and receiver 3 Connect the equipment into an outlet on another ...

Отзывы: