FlexPass OFR100
K02000-000 - 7 - 06/29/01
9. Wire Connection to FlexPass SDC1000 Single Door Controller
10. Operation
10-1. Once power is applied, the Red LED should be on and you should hear three beeping
sounds indicating that the reader is in standby mode after a successful initialization and
diagnostics.
10-2. Present proximity card to the reader until you hear the beeping sound and see the LED
changes color to Green. The reader will send the RF card data to the controller then
the LED will change color to Red again for the next reading.
10-3. LED Control:
To change the LED colors, you may connect the LED Control Input (Brown wire) to
ground and the Green LED will turn on indicating that the reader is in standby mode.
Present proximity card and the LED will change color to Red then Green again for the next
reading.
10-4. Beeper Control:
In normal operation, the reader generates one beep when it reads a proximity card,
however additional beeps can be generated to improve indication for access status (granted
or dinied) by forcing the beeper control input, blue wire to system ground level. The beeper
will remain on as long as the blue wire is connected to system ground.