DDS/MR64
3-1
Chapter 3
Operation
GENERAL
After completing installation, the unit is ready for operation and config-
uration. Most configuration options are soft options and are selected by
the LCD and pushbuttons. Therefore, operation of the unit should be
understood prior to option selection. Hard options are described at the
end of Chapter 4.
The DDS/MR64 requires no start up procedure. After installation and
configuration, the DDS/MR64 will perform all configured functions.
DATA TERMINAL EQUIPMENT (DTE)
The DTE interface to the DDS/MR64 is through a 25-pin, D-type
connector. The sense levels and impedances conform to either EIA-232
or CCITT V.35 INTERFACE depending on the option switch selected.
The type of DTE interface selected in the unit is displayed on power-up.
DTE INTERFACE CONNECTORS
Pin functions of the DTE interface connector are listed in Table 3-1 and
Table 3-2.
Table 3-1. CCITT/EIA-232 Connector
Circuit
Function
Pin
CCITT/
RS-232
Protective ground
1
101/AA
Signal ground
7
102/AB
Request to Send (RTS)
4
105/CA
Clear to Send (CTS)
5
106/CB
Data Set Ready (DSR)
6
107/CC
Received Line Signal Detector (RLSD)
8
109/CF
Test mode
†
25
142
No signal
†
12
110/CG
Rx data
3
104/BB
Rx clock
17
115/DD
Tx clock
15
114/DB
Содержание DDS/MR64
Страница 4: ...iv ...
Страница 10: ...Table of Contents x DDS MR64 Appendix A Specifications ...
Страница 14: ...Introduction 1 4 DDS MR64 ...
Страница 18: ...Installation 2 4 DDS MR64 ...
Страница 28: ...Operation 3 10 DDS MR64 ...
Страница 44: ...Configuration 4 16 DDS MR64 ...
Страница 54: ...Troubleshooting 6 4 DDS MR64 ...
Страница 58: ...Non DDS Applications 7 4 DDS MR64 ...
Страница 62: ...Maintenance 9 2 DDS MR64 ...
Страница 64: ...Specifications A 2 DDS MR64 ...