Configuration
DDS/MR64
4-3
RTS Control
RTS CONT
The RTS control options are as follows:
•
Normal - Normal DTE controlled RTS.
•
Permanent - Provides a permanent RTS and CTS.
•
35 sec AS - 35 second anti-streaming terminal disconnect. In this
mode, if RTS is on from the DTE for 35 continuous seconds, the
DDS/MR64 turns CTS OFF.
•
SIM SW CR - Simulated switched carrier. Provides a permanent
RTS to the DSU/CSU. CTS to the DTE is controlled by and follows
RTS from the DTE.
•
SIM SW CR A-STRM - Enables both the SIM SW CR option and
the 35 sec AS option.
☞
Note
The behavior of CTS once RTS is raised by the DTE may
depend on the status of the Circuit Assurance OPTion (CA
OPT). Refer to Chapter 4, Circuit Assurance.
Buffer
BUFF OPT
This option is used to buffer externally clocked transmitted data and can
be enabled or disabled. The option is used mainly with a crossover cable
in tail circuit applications. When enabled, transmit data from the DTE is
clocked into the buffer using the external clock from the DTE. Data is
clocked from the buffer to the DDS line using the clock from the DDS/
MR64 (usually in DDS timing). The RTS CONT option should be set
for normal. This option is intended for use in a polled system (RTS is
toggled). If the TIMING option is selected for EXTERNAL, this option
does not apply and is not displayed.
Loopback
LB OPT
The remote loopback (RMT LB) feature may be enabled or disabled to
avoid accidental activation.
DSR
DSR OPT
DSR can be on or off during loopback modes.
Содержание DDS/MR64
Страница 4: ...iv ...
Страница 10: ...Table of Contents x DDS MR64 Appendix A Specifications ...
Страница 14: ...Introduction 1 4 DDS MR64 ...
Страница 18: ...Installation 2 4 DDS MR64 ...
Страница 28: ...Operation 3 10 DDS MR64 ...
Страница 44: ...Configuration 4 16 DDS MR64 ...
Страница 54: ...Troubleshooting 6 4 DDS MR64 ...
Страница 58: ...Non DDS Applications 7 4 DDS MR64 ...
Страница 62: ...Maintenance 9 2 DDS MR64 ...
Страница 64: ...Specifications A 2 DDS MR64 ...