A-12
Diagnostics
DCT2500 Installation Manual
The Current Channel Status fields are:
Field Description
Type
Indicates whether the current channel is analog or digital*
Status
Indicates the channel type*
Connected
Indicates whether the set-top is connected*
Preview
Indicates whether the program is in the free preview state: YES or NO.
Purchasable
Indicates whether the current or next program can be purchased: YES or NO.
Purchased
Indicates whether the current or next program has been bought: YES or NO.
CH
Indicates the channel currently tuned when the OSD appeared.
Tuned
Frequency
The actual programmed tuner frequency (Carrier Definition Fre 1.75 MHz).
The EPOCH Number and Type, Authorization, Service Status, and ID are for Motorola use
only
.
* The variables
aaa
,
bb
,
ccccc
, and
ddd
are:
aaa
For analog, it is blank. For digital,
aaa
can be:
!
ENC
−
encrypted
!
UNE
−
unencrypted
The current epoch authorization reason in the current_epoch_auth_reason field (hexadecimal):
00
missing program re-key
01
missing working key epoch message
02
missing event blackout message
03
missing category rekey
04
old category sequence in program, rekey message
10 program
bought
11
program bought without taping
12 subscribed
with
taping
13 subscribed
without
taping
14
subscribed with taping purchasable
15 IPPV
with
taping
16 IPPV
without
taping
20
bad seed checksum
21
bad debit buffer checksum
30
IPPV not enabled
31
insufficient credit to purchase
32
show count limit exceeded
33
debit register will overflow
34
no AFP records available
36
maximum package cost exceeded
37
no IPPV overlay in message
40 not
subscribed
41 regional
blackout
bb
42 event
blackout
ccccc
INIT
−
Initialized state
CONFI
−
Configured
ACQUI
−
Acquiring the program
AUTH
−
Authorized for the program
Not A
−
Not authorized for the program
ddd
blank
−
Connected
NOT
−
Not connected