You can disable the feature temporarily or permanently. This feature allows you to prevent one or all
events from being reported OTA.
This feature is enabled through Customer Programming Software (CPS) configuration. Contact your
system administrator for more information.
NOTICE:
The radio reports the next event after the preprogrammed 15-second timer expires.
Any consecutive event occurring within the timer is not reported to avoid multiple reports over
the same incident.
6.19.12.1
Holster Sensor
Holster sensor monitors the state of the holster and allows the radio to send an over-the-air (OTA)
notification whenever a gun or a taser is pulled out of the holster or put in the holster.
The sensor can cache events that happen when the sensor is disconnected from the radio. When the
sensor is reconnected, the radio evaluates and sends the important events OTA to the system. Check
with your system administrator for more information about these cached events.
If the sensor is disconnected from the radio for more than 30 minutes or it is disabled, the holster
sensor clears the cached events.
6.19.12.2
Weapon Fired Sensor
The feature allows the radio to send an over-the-air (OTA) notification when a weapon enabled with the
sensor is fired. The event is immediately sent to the system to alert the dispatcher of the weapon fired
incident.
6.19.12.3
Vest Pierced Sensor
Vest Pierced sensor is located inside a bulletproof vest. The sensor reports an event to the radio when
the vest is pierced due to various causes such as bullet shot or knife stabbing.
The feature allows the radio to send an emergency message and over-the-air (OTA) notification when
a vest piercing event occurs. The event is immediately sent to the system to alert the dispatcher of the
vest pierced incident.
The receiving radio displays
VPierced RCVD
to indicate that the sender is in a Vest Pierced
Emergency event.
6.19.12.4
Low Battery Notification
When the holster or weapon fire sensor battery is below the preset threshold value, the radio displays
<BT alias> low batt
and a tone sounds.
6.19.12.5
Disabling the Sensor
This feature disables the sensors temporarily or permanently from sending the sensor events to the
system.
NOTICE:
The feature is only applicable to holster sensor and weapon fired sensor. Vest
pierced sensor cannot be disabled.
MN004476A01-AE
Chapter 6: Advanced Features
108