Страница 3: ...recautions 11 1 8 2 Warnings 12 1 9 Access Point Placement 13 1 10 AP 8163 Hardware Overview 13 1 10 1 AP 8163 Ports and Connections 13 1 10 2 AP 8163 Antenna Connectors 14 1 10 3 AP 8163 Grounding Post 16 1 11 LED Indicators 17 2 0 AP 8163 Hardware Mounting and Installation 18 2 1 Mounting Bracket Kit 18 2 1 1 Extension Arm Kit 19 2 2 Pole Mounted Installations 20 2 2 1 Vertical Pole Mount 21 2 2...

Страница 4: ...4 2 Potentially Hazardous Atmospheres 44 5 5 RF Exposure Guidelines 45 5 6 Power Supply 46 5 7 Radio Frequency Interference Requirements FCC 46 5 7 1 Radio Transmitters Part 15 47 5 8 Radio Frequency Interference Requirements Canada 47 5 9 CE Marking and European Economic Area EEA 48 5 10 Statement of Compliance 48 5 11 Turkish WEEE Statement of Compliance 48 5 12 Other Countries 48 5 13 Waste Ele...

Страница 5: ... the availability of network resources including wired networks Once adopted by a Motorola Solutions WLAN or Integrated Services Controller running WiNG 5 6 or higher firmware the AP 8163 is managed as an Adaptive AP running the WiNG 5 network management protocol WiNG 5 networks extend the current differentiation that Adaptive APs offered to the next level by now having the services and security a...

Страница 6: ...l motorolasolutions com Support US EN Wireless Networks Model Part Number Description AP 8163 66S40 US AP 8163 Access Point outdoor dual radio 3x3 3 802 11n with sensor radio SKU US AP 8163 66S40 WR AP 8163 Access Point outdoor dual radio 3x3 3 802 11n with sensor radio SKU WR AP 8163 66S40 EU AP 8163 Access Point outdoor dual radio 3x3 3 802 11n with sensor radio SKU EU NOTE All AP 8163 Access Po...

Страница 7: ...9 HPA4 01 Dipole ML 2499 HPA8 01 Dipole ML 2452 HPAG4A6 01 Dipole ML 2452 APA2 01 Dipole ML 2452 HPA5 036 Dipole ML 2452 HPA6M6 072 Dipole ML 2452 HPA6X6 036 Dipole ML 2452 HPAG5A8 01 Dipole ML 2452 APAG2A1 01 Dipole ML 2499 5PNL 72 N Panel ML 2452 PNA5 01R Panel ML 2452 PNA7 01R Panel ML 2452 PNL9M3 036 Panel ML 2452 PTA6M6 036 Panel ML 2452 PNL3M3 1 Panel ML 2499 SD3 01R Patch ...

Страница 8: ...G2A1 01 Dipole ML 2452 HPA5 036 Dipole ML 2452 HPA6M6 072 Dipole ML 2452 HPA6X6 036 Dipole ML 5299 HPA10 01 Dipole ML 2452 HPAG4A6 01 Dipole ML 2452 HPAG5A8 01 Dipole ML 5299 FHPA10 01R Dipole ML 2452 PNA5 01R Panel ML 2452 PNA7 01R Panel ML 2452 PTA6M6 036 Panel ML 2452 PNL3M3 1 Panel ML 2452 PNL9M3 036 Panel ML 5299 WPNA1 01R Panel ML 5299 PTA1 01R Patch ML 5299 BYGA15 012 Yagi ...

Страница 9: ...163 Weatherized Ethernet Accessory One RJ45 weatherized connector plug is included with each AP 8163 Access Point If additional plugs are required they can be ordered using the part number listed in the following table Part Number Description AP PSBIAS 7161 US Outdoor IP66 802 3AT gigabit Ethernet power injector 100 240 VAC US AP PSBIAS 7161 WW Outdoor IP66 802 3AT gigabit Ethernet power injector ...

Страница 10: ... Solutions Support immediately Each AP 8163 model see AP 8163 Hardware on page 6 includes the following parts AP 8163 Access Point Weatherproof RJ45 plug kit AP 8163 Access Point Installation Guide this document 1 8 Hardware Installation Guidelines NOTE Record the serial numbers on the shipping cartons and AP 8163 Access Points for warranty claims and reference during software download procedures ...

Страница 11: ...tach the grounding cable to the Access Point refer to AP 8163 Grounding Post on page 16 For Ethernet and lightning protection it is recommended that a commercially available off the shelf Lightning Protection Unit LPU be used on all shielded CAT5E Ethernet connections The LPU should be rated for outdoor use For the best possible protection each Access Point requires an LPU be installed adjacent to...

Страница 12: ...quipment or work with its power circuits during thunderstorms or other weather conditions that could cause a power surge Verify there is adequate ventilation around the device and that ambient temperatures meet equipment operation specifications Avoid contact with overhead power lines Take precautions to avoid injury from falling tools and equipment Crews should wear hard hats in and around the in...

Страница 13: ...n deploying devices 1 10 AP 8163 Hardware Overview AP 8163 models have two band unlocked radios that can operate across the 2 4GHz and 5GHz bands subject to country regulatory approval and outdoor band use An AP 8163 must be installed by trained professionals familiar with RF planning and regulatory limits defined by the regulatory bodies of the country where the devices are being deployed All com...

Страница 14: ... marked R2 A R2 B and R2 C these antenna ports relate to the software settings of radio 2 Care must be taken to provide the correct antenna for the operating band of each port AP 8163 three radio models AP 8163 66S40 US AP 8163 66S40 WR and AP 8163 66S40 EU are configured with eight N type connectors to support two active WLAN data radios and a dedicated sensor radio as the third As with the two r...

Страница 15: ...ntenna should be mounted on the unit for sensor operation NOTE The sensor radio does not function as a WLAN data radio WARNING Antenna ports where no antenna is mounted must be properly terminated using an approved IP67 terminator WARNING All antenna connectors should be covered with weatherproofing tape ...

Страница 16: ...to securely attach the grounding cable to the grounding post Use an 8mm socket and driver to tighten the grounding screw to 30 inch pounds lbf in Attach a ring lug to the grounding cable and use a grounding screw to securely attach the ring lug to the Access Point Use an 8mm socket and driver to tighten the grounding screw to 30 inch pounds lbf in WARNING The grounding cable for an AP 8163 must be...

Страница 17: ...ond interval If this radio band is disabled Off If there is activity on this band Blink interval at 1 time per second If this radio band is enabled Blink at 5 second interval If this radio band is disabled Off If there is activity on this band Blink interval at 1 time per second Firmware Update Off On Locate AP Mode LEDs blink in an alternating green red and amber pattern using an irregular blink ...

Страница 18: ...ting bracket kit KT 147407 01 includes the Access Point bracket left angle adapter bracket center and pole mount bracket right sections The Access Point bracket and angle adapter bracket can be rotated plus or minus 15 degrees and tilted up to 45 degrees to orient the unit for optimal positioning The following ancillary hardware to assemble the mounting bracket sections is included in the kit A to...

Страница 19: ...s more than 3 inches in diameter use the extension arm kit KT 150173 01 to provide a minimum standoff distance of twelve inches to avoid interference with the antennas The extension arm kit can also be used in combination with the any of the brackets from the mounting bracket kit ...

Страница 20: ...ket of the mounting hardware kit at the desired position on the pole using band clamps up to 3 4 inch width or a 1 2 inch x 4 inch wide U bolt and nuts For poles greater than 3 inches in diameter attach the pole mount bracket using band clamps Description Quantity 1 2 inch hex head nut 2 1 2 inch x 3 4 inch hex head bolt 2 CAUTION Always mount the AP 8163 with the black gore vent facing down NOTE ...

Страница 21: ... nuts onto the U bolt 2 Position the U bolt on the pole and place the pole mount bracket section on the U bolt Adjust the two 1 2 inch inner nuts until the pole mount bracket section is against the pole and the U bolt can be secured tightly to the pole at the desired mounting location 3 Place the angle adapter bracket section on the U bolt with the open slot connections on the bottom and align it ...

Страница 22: ...nted toward the bottom side of the AP with the gore vent Using a torque wrench or a ratchet and a 10mm socket or an adjustable wrench attach but don t tighten the Access Point bracket section to the AP 8163 with the four M6 flange screw 5 Insert two M6 hex flange screws into the bottom holes on the sides of the Access Point bracket section ...

Страница 23: ...sides of the Access Point bracket section into the open slot connections on the bottom of the angle adapter bracket section 7 Rotate the Access Point bracket section upward and align the top holes on the sides with the top holes on the angle adapter bracket section Insert two M6 hex flange screws into the top holes on the angle adapter bracket section ...

Страница 24: ...dapter bracket section positioned so the open connector slots are on the bottom attach the angle adapter bracket section to the pole mount bracket section using two 1 2 inch bolts and nuts Tighten the nuts to 300 inch pounds lbf in 3 Position the Access Point bracket section so the bottom of the section with the straight not bevel cut sides is oriented toward the bottom side of the AP with the gor...

Страница 25: ...s and the top holes on the angle adapter bracket section Do not tighten the screws until all rotation and tilt adjustments are complete 7 To adjust the position of the Access Point rotate the Access Point bracket section plus or minus 15 degrees and tilt the angle adapter bracket section up to 45 degrees 8 Tighten all hex flange screws to 60 inch pounds lbf in To use the extension arm with the mou...

Страница 26: ...our M6 hex flange screws The two oval holes must be positioned on the short sides of the Access Point Tighten the hex flange screws to 60 inch pounds lbf in the unit 4 With the Access Point positioned so the gore vent is facing down attach the extension arm to the Access Point bracket section with two 1 2 inch bolts and nuts Tighten the nuts to 300 inch pounds lbf in ...

Страница 27: ...lag bolts 2 Using a torque wrench or a ratchet and a 10mm socket or an adjustable wrench attach but don t tighten the Access Point bracket section to the AP 8163 with four M6 hex flange screws and insert two M6 hex flange screws into the bottom holes on the sides of the Access Point bracket section CAUTION Always mount the AP 8163 with the black gore vent facing down NOTE The U bolt and band clamp...

Страница 28: ...not tighten the screws until all rotation and tilt adjustments are complete 5 To adjust the position of the Access Point rotate the Access Point bracket section plus or minus 15 degrees and tilt the angle adapter bracket section up to 45 degrees 6 Use a torque wrench or a ratchet and a 10mm socket or an adjustable wrench to tighten all screws when all adjustments are complete 7 Tighten all hex fla...

Страница 29: ...in 100 meters of the controller and a PoE port is available the AP 8163 Access Point can also be connected directly to a Motorola Solutions WLAN or Integrated Services Controller running WiNG 5 6 or higher A standard CAT5E cable can be used to provide the connection to the AP 8163 The GE1 POE port on the AP 8163 is where the standard CAT5E cable will connect to the Access Point and use of the weat...

Страница 30: ...dress from the AP MAC address Using this method the last two bytes of the MAC address become the last two octets of the IP address For example MAC address 00 C0 23 00 F0 0A Zero Config IP address 169 254 240 10 To derive the Access Point s IP address using its MAC address a Open the Windows calculator be selecting Start All Programs Accessories Calculator This menu path may vary slightly depending...

Страница 31: ...6 If this is the first time the management interface has been accessed the Initial Setup Wizard automatically displays NOTE When logging in for the first time you re prompted to change the password to enhance device security in subsequent logins NOTE If you get disconnected when running the wizard you can connect again with the Access Point s actual IP address once obtained and resume the wizard ...

Страница 32: ...nitial Setup Wizard displays the Navigation Panel and Function Highlights for the configuration activities comprising the Access Point s initial setup This page also displays options to select the typical or advanced mode for the wizard The Navigation Panel for the Typical Setup Wizard displays the basic configuration options A green checkmark to the left of an item in the Navigation Panel defines...

Страница 33: ...e to familiarize yourself with the feature set supported by the WiNG operating system The guide is available at https portal motorolasolutions com Support US EN Wireless Networks To configure the Access Point using the Typical Setup Wizard 8 Select Typical Setup from the Choose One type to Setup the Access Point field on the Initial Setup Wizard 9 The Typical Setup Wizard displays the Access Point...

Страница 34: ...critical task while configuring the Access Point as it defines the correct channels of operation and ensures compliance to the regulations of the selected country This field is only available for the Typical Setup Wizard 12 Select Next to set the Access Point s network mode NOTE If wanting to adopt the Access Point to a controller or service platform use the controller or service platform s reside...

Страница 35: ...d in a deployment supported by just a single Access Point Bridge Mode In Bridge Mode the Access Point depends on an external router for routing LAN and WAN traffic Routing is generally used on one device whereas bridging is typically used in a larger density network Select Bridge Mode when deploying this Access Point with numerous peer Access Points supporting clients on both the 2 4GHz and 5GHz r...

Страница 36: ...selecting this option define the following DHCP Server and Domain Name Server DNS resources as those fields will become enabled on the bottom portion of the screen Use on board DHCP server to assign IP addresses to wireless clients Select the checkbox to enable the Access Point s DHCP server to provide IP and DNS information to clients on the LAN interface Range Enter a starting and ending IP Addr...

Страница 37: ... SSID for the WLAN WLAN Type Configure the encryption and authentication to use with this WLAN No Authentication and No Encryption Configures a network without any authentication This option also configures the network without encryption This means that any data transmitted through the network is in plain text Any device between end points can see the information transmitted This is the least secu...

Страница 38: ...e RADIUS Server Configuration screen if required Otherwise the Typical Setup Wizard displays the Summary and Commit screen 20 Use the Radius Server Configuration screen to configure the users for the onboard RADIUS server Use the screen to add modify and remove RADIUS users ...

Страница 39: ...r user select Create To create the entry in the RADIUS server database and close the Add User dialog select Create Close 24 Select Modify User on the RADIUS Server Configuration screen to modify information for an existing user from the RADIUS database Highlight the user entry then select Modify User 25 Select Delete User on the RADIUS Server Configuration screen to remove information for an exist...

Страница 40: ...efore it s deployed However if a screen displays settings not intended as part of the initial configuration then any screen can be selected again from within the Navigation Panel and its settings modified accordingly 29 If the configuration displays as intended select Save Commit to implement these settings to the Access Point s configuration If additional changes are warranted based on the summar...

Страница 41: ...BaseT Ethernet 802 3at on GE1 LAN port Antenna Connectors 8 N Type console ports Console Port Outdoor rated RJ45 console port Multi Band Security Sensor Outdoor 24x7 Wireless Intrusion Prevention System WIPS Operating Temperature 22 F to 140 F 30 C to 60 C Storage Temperature 40 F to 185 F 40 C to 85 C Operating Humidity 5 to 95 RH non condensing IP Sealing IP 67 Operating Altitude 8 000 ft at 12 ...

Страница 42: ...42 AP 8163AccessPoint 4 3 Power Characteristics Operating Voltage 36 57 VDC Operating Current 625mA at 48V in 802 3at mode Integrated PoE 802 3at ...

Страница 43: ...antennas Unauthorized antennas modifications or attachments could cause damage and may violate regulations 5 1 Wireless Country Approvals Regulatory markings are applied to the device signifying the radio s are approved for use in the following countries United States Canada Australia and Europe Please refer to the Declaration of Conformity DoC for details of other country markings This is availab...

Страница 44: ...in de réduire les risques de brouillage préjudiciable aux systèmes de satellites mobiles utilisant les mêmes canaux Les utilisateurs de radars de haute puissance sont désignés utilisateurs principaux c à d qu ils ont la priorité pour les bands 5250 5350 MHz et 5650 5850 MHz et que ces radars pourraient causer du brouillage et ou des dommages aux dispositifs LAN EL 5 4 Health and Safety Recommendat...

Страница 45: ...e in accordance with the instructions supplied International The device complies with internationally recognized standards covering human exposure to electromagnetic fields from radio devices For information on International human exposure to electromagnet fields refer to the Motorola Declaration of Conformity DoC at http www motorolasolutions com doc For further information on the safety of RF en...

Страница 46: ...ply will invalidate any approvals given to this unit and may be dangerous 5 7 Radio Frequency Interference Requirements FCC This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates ...

Страница 47: ...el Marking The Term IC before the radio certification only signifies that Industry Canada technical specifications were met To reduce potential radio interference to other users the antenna type and its gain should be so chosen that the equivalent isotropically radiated power EIRP is not more than that permitted for successful communication The device could automatically discontinue transmission i...

Страница 48: ...P 8163 5 9 CE Marking and European Economic Area EEA The use of 2 4 GHz RLAN s for use through the EEA have the following restrictions Maximum radiated transmit power of 100 mW EIRP in the frequency range 2 400 2 4835 GHz Italy requires a user license for outside usage 5 10 Statement of Compliance Motorola Solutions hereby declares that this device is in compliance with the essential requirements ...

Страница 49: ...secretaria de telecomunicaciones relativa a radiaciones electromagnéticas China http www motorolasolutions com CN ZH Pages Contact_Us support_tab http www tenaa com cn Hong Kong In accordance with HKTA1039 the band 5 15GHz 5 35GHz is for indoor operation only Mexico Restrict Frequency Range to 2 450 2 4835 GHz La operación de este equipo está sujeta a las siguientes dos condiciones 1 es posible qu...

Страница 50: ...50 AP 8163AccessPoint Taiwan Ukraine Thailand ...

Страница 51: ...lvidos à Motorola Solutions para reciclagem Para obter informações sobre como devolver o produto visite http www motorolasolutions com recycling weee Nederlands Voor klanten in de EU alle producten dienen aan het einde van hun levensduur naar Motorola Solutions te worden teruggezonden voor recycling Raadpleeg http www motorolasolutions com recycling weee voor meer informatie over het terugzenden v...

Страница 52: ...ww motorolasolutions com recycling weee Slovenski Za kupce v EU vsi izdelki se morajo po poteku življenjske dobe vrniti podjetju Motorola Solutions za reciklažo Za informacije o vračilu izdelka obiščite http www motorolasolutions com recycling weee Slovenčina Pre zákazníkov z krajín EU Všetky výrobky musia byť po uplynutí doby ich životnosti vrátené spoločnosti Motorola Solutions na recykláciu Bli...

Страница 53: ...rth in support agreements If you purchased your product from a Motorola Solutions business partner contact that business partner for support Customer Support Web Sites The Motorola Solutions Support Central Web site located at https portal motorolasolutions com Support US EN provides information and online assistance including developer tools software downloads product manuals and online repair re...

Страница 54: ...所有所列的部件 This table was created to comply with China RoHS requirements for the Motorola Solutions AP 8163 model Access Point 部件名称 Parts 有毒有害物质或元素 铅 Pb 汞 Hg 镉 Cd 六价铬 Cr6 多溴联苯 PBB 多溴二苯醚 PBDE 金属部件 Metal Parts X O O O O O 电路模块 Circuit Modules X O O O O O 电缆及电缆组件 Cables and Cable Assemblies X O O O O O 塑料和聚合物部件 Plastic and Polymeric Parts O O O O O O 光学和光学组件 Optics and Optical Components O O O O O O 电池 ...

Страница 55: ...Installation Guide 55 ...

Страница 56: ... MOTOROLA MOTO MOTOROLA SOLUTIOSNS and the Stylized M Logo are trademarks or registered trademarks of Motorola Trademark Holdings LLC and are used under license All other trademarks are the property of their respective owners 2014 Motorola Solutions Inc All Rights Reserved MN000759A01 Revision B May 2014 ...

Отзывы: