With the Access Point positioned so the gore vent is facing down, insert the two M6 hex flange screws
in the bottom holes on the sides of the Access Point bracket section into the open slot connections on the
bottom of the angle adapter bracket section. Rotate the Access Point bracket section upward and align
the top holes on the sides with the top holes on the angle adapter bracket section. Insert two M6 hex
flange screws into the top holes on the angle adapter bracket section.
4.
Use a torque wrench or a ratchet and a 10mm socket, or an adjustable wrench, to finish attaching the
angle adapter bracket section to the Access Point bracket section with the four M6 hex flange screws in
the open slot connections and the top holes on the angle adapter bracket section. Do not tighten the
screws until all rotation and tilt adjustments are complete.
5.
To adjust the position of the Access Point, rotate the Access Point bracket section (plus or minus 15
degrees) and tilt the angle adapter bracket section (up to 45 degrees).
6.
Use a torque wrench or a ratchet and a 10mm socket, or an adjustable wrench, to tighten all screws when
all adjustments are complete.
7.
Tighten all hex flange screws to 60 inch pounds (lbf-in).
To use the extension arm with the mounting hardware kit:
1.
With the open slot connections facing down, attach the angle adjust bracket section at the desired
mounting location using four #10/32 lag bolts.
2.
Complete the steps for assembling and positioning the angle adapter bracket and Access Point bracket
sections outlined above. See
Vertical Pole Mount on page 21
.
3.
With the Access Point positioned so the gore vent is facing down, attach the extension arm to the Access
Point bracket section with two ½ inch bolts and nuts. Tighten bolts to 300 inch pounds (lbf-in).