MOTOROLA

 and the Stylized M Logo are registered in the US Patent & Trademark Office. 

AirDefense is a registered trademark of AirDefense, Inc. All other product or service names 
are the property of their respective owners. © Motorola, Inc. 2008. All rights reserved.

Содержание AirDefence

Страница 1: ...INSTALLATION Server Appliance Installation Guide ...

Страница 2: ......

Страница 3: ... 2 3 Cautionary Statements 4 3 0 Installation Steps 6 3 1 Step 1 Install the AirDefense Server Appliance 6 3 2 Step 2 Power up the Appliance 7 3 3 Step 3 Launch the Command Line Interface WIPSadmin 9 3 4 Step 4 Configure Time Settings TZ and Time 9 3 5 Step 5 Configure the IP Address IP 11 3 6 Step 6 Create a User with admin Privileges WEBU 12 Contents ...

Страница 4: ...liance GUI 13 3 8 Step 8 Use the System Setup Wizard for Initial Configuration 19 4 0 Regulatory Information 25 Waste Electrical and Electronic Equipment WEEE 27 5 0 Part Numbers Support and Sales 29 6 0 Master License Agreement for the AirDefense System 30 ...

Страница 5: ... M Logo are registered in the US Patent Trademark Office AirDefense is a registered trademark of AirDefense Inc All other product or service names are the property of their respective owners Motorola Inc 2008 All rights reserved ...

Страница 6: ......

Страница 7: ...nse does not require an enterprise to buy install configure lockdown and support a server operating system and database A true appliance comes ready with the application and all supporting software pre loaded 1 1 Document Conventions The following graphical alerts are used in this document to indicate notable situations NOTE Tips hints or special requirements that you should take note of CAUTION C...

Страница 8: ...ration of the equipment Do not work with power circuits in dimly lit spaces Do not install this equipment or work with its power circuits during thunderstorms or other weather conditions that could cause a power surge Verify there is adequate ventilation around the device and that ambient temperatures meet equipment operation specifications 1 3 Site Preparation Consult your site survey and network...

Страница 9: ...il and attachment from AirDefense AirDefense License located in the shipping email and attachment from AirDefense IP address subnet mask FQDN or domain name of any devices you want to use in a SSH connection to the appliance Decide whether to specify time settings or use an NTP server If you want to use an NTP server you need the IP or FQDN of the server Network Information IP address subnet mask ...

Страница 10: ...e appliance GUI 8 Use the System Setup Wizard for initial configuration 2 3 Cautionary Statements CAUTION AirDefense highly recommends that you change all passwords at your earliest opportunity CAUTION There are no user serviceable components inside the AirDefense Server Opening the chassis will void the warranty CAUTION The recommended ambient operating temperature of the AirDefense Server applia...

Страница 11: ...r is powered can safely accommodate a 250 Watt power supply for the Model 1250 3650 appliance or a 500 Watt power supply for the Model 4250 appliance CAUTION AirDefense highly recommends that you connect the AirDefense Server to a UPS uninterruptible power supply There are instances in which the system software could become corrupt and un recoverable in the event of power loss for example during a...

Страница 12: ...AirDefense Server in an equipment rack using the rails provided 2 Connect the AirDefense Server to the network using the 10 100 LAN port on the back panel See the next section for more information 3 For first time installation set up the AirDefense Server locally Connect the keyboard and monitor to the AirDefense Server using the video and keyboard ports on the back panel Model 1250 Model 3650 App...

Страница 13: ... appliance to the On 1 position See previous rear view appliance graphics Then press the Power On button green LCD check button for 1 second MODEL 1250 AND MODEL 3650 APPLIANCE Revision Number Ethernet Port Location on Back Panel Revision 1 0 MODEL 4250 APPLIANCE Revision Number Ethernet Port Location on Back Panel Revision 2 0 Revision 1 0 NOTE The Model 4250 appliance does not have a rear On Off...

Страница 14: ...d if only one Power Supply is working or plugged in the alarm will sound You can reset the power supply alarm by pressing the red button on the back of the appliance NOTE The red LCD X button is the Power Off button Press this button for 4 seconds to power down the system NOTE Press and hold green LCD check button for 4 seconds or more to restart appliance ...

Страница 15: ...oftware and Configuration 1 Turn on power to the AirDefense Server The AirDefense Server boots up and a Command Line login prompt displays 2 Type the Default Command Line User account name smxmgr and then press Enter 3 Type the default Command Line User password smxmgr and then press Enter 4 Type WIPSadmin case sensitive at the prompt The WIPSadmin main screen displays 5 Go to the next step Config...

Страница 16: ...e current settings for date and time 7 Type the date in MMDDYYYY format and then press Enter Do not use colons or forward slashes 8 Type the time in 24 hour HHMM or HHMMSS format and then press Enter 9 Type yes to save your changes and then press Enter The Config screen displays Do not exit WIPSadmin This will cause the system to reboot 10 Go to Step 5 Configure the IP Address Alternative B Specif...

Страница 17: ...eway of the AirDefense Server DHCP is enabled by default 1 At the command prompt on the WIPSadmin main screen type c and then press Enter The Config screen displays 2 Type IP at the prompt and then press Enter The IP address config screen displays The screen displays the current network configuration ...

Страница 18: ...admin Privileges WEBU To log into the GUI to continue configuring and begin managing the AirDefense system you will need to establish at least one user with the role of admin 1 From the WIPSadmin screen type m and then press Enter The Manage screen displays 2 Type webu and then press Enter WIPSadmin displays a list of current users and roles 3 If the default admin user is listed and you have not c...

Страница 19: ...se a workstation with internet connectivity 1 Launch a browser and navigate to one of the following https server_ip_address 8543 https server_name 8543 The thin client login page displays It includes both Windows and Linux installers CAUTION AirDefense automatically reboots when you exit the Command Line Interface Do not just close the SSH client Instead continue typing q until you quit the Comman...

Страница 20: ...ur OS A File Download window displays From this window you can run the installer now or save the installation file to your workstation and run it later 3 Click Run to install the software now The installation file downloads to your workstation and starts the installation process A License Agreement displays before the installation begins ...

Страница 21: ...ent and then click I Agree The installation location window displays 5 Accept the default location or browse to another location and then click Install The installation program installs the AirDefense application and then displays the finish screen ...

Страница 22: ...allation Guide 16 6 To start the application leave the Run AirDefense checkbox selected To create a shortcut on your desktop leave the checkbox selected and then click Finish The AirDefense Enterprise log in screen displays ...

Страница 23: ... your shipment notification email The following screen displays This is the Master License Agreement for the AirDefense System It will only display when you access the GUI after an installation You must agree to accept this agreement to continue 8 Click Accept to continue The next screen displays ...

Страница 24: ...m the GUI by selecting Configuration Configuration Wizard More details are provided in the Online Help and User Guide Restore a saved configuration this option allows you to restore a saved configuration after a system backup has been executed More details are provided in the Online Help and User Guide Go directly to the dashboard this option displays the GUI in Dashboard view 9 Click Configure us...

Страница 25: ...s the following pages Setup System Settings Define Network Structure Create User Accounts Define Policies Configure Alarms Schedule Auto Classification Configure Actions Import Devices You can exit the wizard at any time and use it again later As you make changes to the pages the wizard displays blue asterisks next to the page names to help you track which pages you have worked on When you are fin...

Страница 26: ...tructure and place sensors in them Alternative navigation Configuration Configuration Wizard Define Network Structure Use the buttons along the top of the tree window to Add a new Location Add a new Group Delete a Location Group or Sensor Select a Location Group or Sensor and move it up in the tree Select a Location Group or Sensor and move it down in the tree To add a name or description for a Lo...

Страница 27: ...the privacy policy Base Authentication Extended Authentication Key Generation Encryption You can use the Policy Manager to create additional policies with alternative settings Select Configuration Policy Management Configure Alarms The Configure alarms page provides three pre defined Security Sensitivity modes to let you quickly specify the alarms you want to enable You can use the pre defined pol...

Страница 28: ...s it detects in your wireless network as Authorized Unauthorized Ignored or to be deleted You should periodically have the application reclassify devices In environments with many transient devices this can help you limit the alarm count caused by unauthorized devices This page lets you define the rules that the system will use to automatically classify each device It also lets you schedule auto c...

Страница 29: ...ering a name in the Settings tab 3 Select the Actions tab then the Add button to add an action 4 Define an action Available Actions are Termination Port Suppression ACL Report E Mail Syslog Snp Trap Frame Capture 5 Select the Filter tab and select a scope an alarm and specify any exceptions 6 Select the Advanced Filter tab and define a filter list as appropriate 7 Return to the Settings tab and se...

Страница 30: ...e navigation Configuration Configuration Wizard Import Devices 1 To import a file select Load AP File or Load Station File 2 Browse to the file location select the file and then click Open A status window displays displaying the number of lines processed and any error messages 3 Click Close You can import additional devices by selecting Configuration Policy Manager ...

Страница 31: ...2 2001 The laser classification is marked on the device Class 1 Laser devices are not considered to be hazardous when used for their intended purpose The following statement is required to comply with US and international regulations Radio Frequency Interference Requirements FCC This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of t...

Страница 32: ... is a Class A product based on the standard of the Voluntary Control Council for Interference by Information Technology Equipment VCCI If this equipment is used in a domestic environment radio interference may occur in which case the user may be required to take corrective actions Marking and European Economic Area EEA CAUTION This is a class A product In a domestic environment this product may ca...

Страница 33: ...zur Rücksendung von Produkten finden Sie unter http www symbol com environmental_compliance Eesti EL klientidele kõik tooted tuleb nende eluea lõppedes tagastada taaskasutamise eesmärgil Symbol ile Lisainformatsiooni saamiseks toote tagastamise kohta külastage palun aadressi http www symbol com environmental_compliance Español Para clientes en la Unión Europea todos los productos deberán entregars...

Страница 34: ...ienen aan het einde van hun levensduur naar Symbol te worden teruggezonden voor recycling Raadpleeg http www symbol com environmental_compliance voor meer informatie over het terugzenden van producten Português Para clientes da UE todos os produtos no fim de vida devem ser devolvidos à Symbol para reciclagem Para obter informações sobre como devolver o produto visite http www symbol com environmen...

Страница 35: ...mber Motorola responds to calls by email telephone or fax within the time limits set forth in support agreements If you purchased your Enterprise Mobility business product from a Motorola business partner contact that business partner for support Customer Support Web Site Motorola s Support Central Web site accessed via the Symbol branded products link under Support for Business provides informati...

Страница 36: ...process Licensee s own data and may not rent or sell the Products or use thereof to any third party Any other individual or company including any of Licensee s parent subsidiary or affiliate entities shall require a separate license to use the Products or any part thereof Licensee may not transfer any part of the Products or any rights hereunder to any third party without the express written conse...

Страница 37: ... nature that is levied or imposed by any governmental authority on Licensee s purchase license of the Products this Agreement or Licensee s use of the Products or Documentation 10 Export Restrictions THIS AGREEMENT IS SUBJECT TO ALL LAWS REGULATIONS ORDERS OR OTHER RESTRICTIONS WHICH MAY BE IMPOSED FROM TIME TO TIME BY THE GOVERNMENT OF THE UNITED STATES OF AMERICA ON THE EXPORT OF THE PRODUCTS OR...

Страница 38: ...are and Documentation and Products and support services pricing limitation of liability indemnification and warranty terms are confidential and constitute valuable trade secrets of AirDefense Licensee agrees to take all reasonably necessary action to protect such confidential and proprietary information including appropriate instruction and agreement with employees and agents of Licensee In the ev...

Страница 39: ......

Страница 40: ...MOTOROLA INC 1303 E ALGONQUIN ROAD SCHAUMBURG IL 60196 http www motorola com Revision A January 2009 ...