7. Commissioning

 

 
Once the system has been fully fitted and connected to control panel (MC2), the system needs to be 
fully commissioned and tested. 
It is recommended to have the swing gates locked into the half open / closed on the first operation, 
just to ensure that the motor is running the right direction on the first command. 
Pay special attention to safety devices. 
Check the control panel logic and set up to ensure all suitable functions are activated and 
programmed properly. 
Fully explain the system to the end user and demonstrate the functions and features that have been 
set up. 
Demonstrate the manual release mechanism as shown in below. 
 
 
 
Turn release key ‘Anti-Clockwise’ 
To unlock Ram (manual) 

Turn release key 
‘Clockwise’ to lock Ram on 

 
 
 
 
 
 
The automated gate system must be used with due care and attention at all times. 
 
Basic maintenance should be carried out at regular intervals to ensure that the gate system is 
operating correctly and safely. 
 

Description of maintenance 

Maintenance 

Schedule 

Clean and check safety Photocells and functions 

Monthly 

Check free movement of gate manually 

Monthly 

Clean foliage or insects from gate or control box 

Monthly 

Check the force of the gate leaf when moving 

6 Monthly 

 
Always consult a specialist if any problems occur which are not solved by basic maintenance  
Always isolate and disconnect power supply to gate control board and motor before opening control 
box or gate motor 
 

Basic Troubleshooting for incorrect operation of motor and control 

Check the power supply and continuity using suitable meter instrument after open and closed 
commands have been given. 

If the motor direction is incorrect, such as the gate leaf closes when it has been given an open 
command, the motor wiring will need to be inverted (see wiring instructions for MC2 control 
panel). Swap the motor phase wires on control panel 

If the gate control panel has a problem, disconnect all additional equipment such as intercoms, 
safety photocells, push buttons etc. Then run tests on the basic system, then re-connect each 
item of equipment individually and test system until the faulty device has been found and 
isolated. 

Содержание SP WING 400

Страница 1: ...1 WING 300 400 600 Operating and installation instructions...

Страница 2: ...f the gate Safety devices should be checked on a monthly basis The gate motor should be kept clean at all times The mechanical parts of the gate motor conform to standards EN12604 and EN12605 It is th...

Страница 3: ...ons Monthly Check free movement of gate manually Monthly Clean foliage or insects from gate or control box Monthly The Wing ram is an electro mechanical gate operator which drives the gate by worm scr...

Страница 4: ...hed wheel Cog 28 1 100624 Aluminium Unclamping 11 3 100789 Ring E20 29 2 100657 O Ring 12 1 100709 Bearing 6004 ZZ 30 1 100825 Front mounting wall bracket 13 2 100658 Towing Ball 31 1 100654 Ram Brack...

Страница 5: ...150 C Frequency of use 35 35 35 Lubrication GREASE GREASE GREASE 3 Pre liminary checks Installation Ensure the gate leaf is securely installed and has no signs of wear The gate must be fixed on suita...

Страница 6: ...le 95 Opening Angle 120 W X Y Z W X Y Z WING 300 930 140 140 370 930 170 120 370 WING 400 1130 185 185 270 1130 250 130 470 WING 600 1540 280 280 670 1540 350 140 670 5 Installation 1 Once the geometr...

Страница 7: ...x the front mounting bracket to the gate leaf whilst ensuring the slight motor incline as mentioned above Fix the motor to the front bracket by pin and grub screw See Items 31 and 26 on the exploded d...

Страница 8: ...maintenance Maintenance Schedule Clean and check safety Photocells and functions Monthly Check free movement of gate manually Monthly Clean foliage or insects from gate or control box Monthly Check th...

Отзывы: