background image

4A

4B

24AC

+ BAT -

MOT

+ LED -

V+

SEN PUL BL

DS

ANT

GND

GND

GND

LIGHT

VR1

+

-

SEL

SET

MONO TEMP. I.CMD

12V

24V

0V

EN

EN

06

02

01

04

03

05

MPIE10 pillars were developed for traffic control, limiting the passage of vehicles. 

Built entirely in 304 stainless steel and PVC, they are anti-vandalism pillars, suitable for underground 

installation.

The kit is composed by the following components:

02. AUTOMATISM

02. AUTOMATISM

TECHNICAL CHARACTERISTICS

KIT COMPONENTS

01 

• 01 MSC50 twilight sensor

02

 • 01 MC61PL Control board

03

 • 01 Integrated RGB LED module

04

 • 01 MPIE10

05

 • 02 FALK remote controllers

06

 • 01 12 Vdc Battery

400

600

800

• Course

370mm

570mm

785mm

 • Weight

35Kg

40Kg

45Kg

 • Power Supply

24 Vdc

 • Power

150W

 • Nominal power consumption

3A

 • Operating Temperature

-20˚C ~ 50˚C

 • Material of the moving piece

2.5mm Stainless steel

 • Cover

Non-slip 4mm Stainless steel

 • Material of the embedded piece

10mm PVC

 • Diameter 

Ø204mm

 • Top flange

400mm

 • Maximum weight supported

20.000Kg

To unlock the electromechanical pillar, insert the key into 

the slot and turn in a clockwise direction. 

MANUAL UNLOCKING

• 

Please hold the key to descend the pillar slowly,

because once unlocked, the pillar is free and will

go down if you don’t hold it.

• 

The pillar is equipped with a battery that, in case

of power failure, allows the pillar to be opened (go

down) once. Do not use the pillar again until power 

is restored, because the battery was placed only

for emergency situations and may not have enough 

energy to complete the closure.

Содержание MPIE10

Страница 1: ...v1 0 REV 03 2021 MPIE10 MPIE10 EN INSTALLER AND USER S MANUAL...

Страница 2: ...erial controls etc should not be disposed of as other household waste at the end of its useful life To avoid possible harm to the environment or human health resulting from the uncontrolled disposal o...

Страница 3: ...persons with experienced in terms of usage of the product in a safe manner and who understands the risks and dangers involved Children shouldn t play with the product or opening devices to avoid the...

Страница 4: ...an emergency Ifthesystemrequiresanyrepairormodification unlocktheautomatism turn off the power and do not use it until all safety conditions have been met In the event of tripping of circuits breakers...

Страница 5: ...ight 35Kg 40Kg 45Kg Power Supply 24 Vdc Power 150W Nominal power consumption 3A Operating Temperature 20 C 50 C Material of the moving piece 2 5mm Stainless steel Cover Non slip 4mm Stainless steel Ma...

Страница 6: ...Dimension c 370mm 570mm 785mm 03 INSTALLATION AUTOMATISM INSTALLATION CREATE FOUNDATION Drill a hole on the ground with the necessary dimension for the placement of the pillar taking into account the...

Страница 7: ...E AUTOMATISM INSTALLATION At the base of the pillar place a tube for draining waste water with a minimum inclination of 10 Provide a tube to pass the electric cable to the control board Place sand aro...

Страница 8: ...On there is some security systems malfunction photocells safety edges If START circuits LEDs are turn Op and Cl there is a control device sending permanent signal 3 If the pillar work the problem is o...