3

EN

work of Directive 2009/104/CE of European Parliament and of the 

Council of 16 September 2009.

• Attach the permanent label for the manual release as close as 

possible to the release mechanism.

• Disconnect means, such as a switch or circuit breaker on the electrical 

panel, must be provided on the product’s fixed power supply leads 

in accordance with the installation rules.

• If the product to be installed requires power supply of 230Vac or 

110Vac, ensure that connection is to an electrical panel with ground 

connection.

•The product is only powered by low voltage satefy with central (only 

at 24V motors)

WARNINGS FOR USERS

• Keep this manual in a safe place to be consulted whenever necessary.

• If the product has contact with fluids without being prepared, it 

must immediately disconnect from the power supply to avoid short 

circuits, and consult a specialized technician.

• Ensure that technician has provided you the product manual and 

informed you how to handle the product in an emergency.

• If the system requires any repair or modification, unlock the 

automatism, turn off the power and do not use it until all safety 

conditions have been met.

• In the event of tripping of circuits breakers of fuse failure, locate 

the malfunction and solve it before resetting the circuit breaker or 

replacing the fuse. If the malfunction is not repairable by consult 

this manual, contact a technician.

• Keep the operation area of the motorized gate free while the gate in 

in motion, and do not create strength to the gate movement.

Do not perform any operation on mechanical elements or hinges if 

the product is in motion.

RESPONSABILITY

• Supplier disclaims any liability if:

• Product failure or deformation result from improper installation 

use or maintenance!

• Safety norms are not followed in the installation, use and 

maintenance of the product.

• Instructions in this manual are not followed.

• Damaged is caused by unauthorized modifications

• In these cases, the warranty is voided.

MOTORLINE ELECTROCELOS SA.

Travessa do Sobreiro, nº29

4755-474 Rio Côvo (Santa Eugénia)

Barcelos, Portugal

01. SAFETY INSTRUCTIONS

SYMBOLS LEGEND:

• Important safety 

notices

• Useful information

• Programming 

information

• Potentiometer 

information

• Connectors 

information

• Buttons 

information

Содержание MF2020

Страница 1: ...MF2020 V2 2 REV 04 2022 V0 1 0 V0 2 0 MF2020 EN Compatible hardware versions USER S AND INSTALER S MANUAL ...

Страница 2: ...ustainable reuse of material resources Home users should contact the dealer where they purchased this product or the National Environment Agency for details on where and how they can take these items for environmentally safe recycling Business users should contact their vendor and check the terms and conditions of the purchase agreement This product and its electronic accessories should not be mix...

Страница 3: ...oduct provided that these are supervision and instructions given by persons with experienced in terms of usage of the product in a safe manner and who understands the risks and dangers involved Children shouldn t play with the product or opening devices to avoid the motorized door or gate from being triggered involuntarily WARNINGS FOR TECHNICIANS Before beginning the installation procedures make ...

Страница 4: ... repair or modification unlock the automatism turn off the power and do not use it until all safety conditions have been met In the event of tripping of circuits breakers of fuse failure locate the malfunction and solve it before resetting the circuit breaker or replacing the fuse If the malfunction is not repairable by consult this manual contact a technician Keep the operation area of the motori...

Страница 5: ... photocell columns is identified with a letter The MF2020 is a column photocell developed to safeguard all types of industrial doors sectional and high speed doors up to a maximum width of 10 meters The emitter and receiver create an infrared beam grid offering protection up to 2 5 meters high When the infrared beams are interrupted a signal is sent to the control board Once the detention area is ...

Страница 6: ...rect functioning of the photocells it is necessary to pay attention to some aspects during the installation process Make sure that the lower edge of the photocell columns is aligned with the level of the door in the closed position You should avoid exposing the photocells especially the photocell receiver directly to sunlight Other types of devices that emit infrared light such as photocells and o...

Страница 7: ...hotocell receiver RX in the place to be fixed mark the 4 necessary holes drill and tighten The output of the cables must always face upwards Repeat with the other photocell TX ensuring both columns are at the same height aligned horizontally Adjust the orientation of each column so that they are aligned between them Slightly loosen the clamp screws C Rotate the columns until they are perfectly ali...

Страница 8: ...e 9B Test the functioning of the system by carrying out an opening closing maneuver verifying that the photocells do not interfere with the normal movement of the door Then repeat the maneuver and place yourself in the area protected by the photocells and check if it reverses the direction of maneuver SYNC CABLE Pass the photocell cables through holes centered with the supports B of each column in...

Страница 9: ...QUENTIAL MODE The photocell is able to differentiate between an interruption caused by an object and the movement of the door For this mode to work correctly the door must be opaque SEQUENTIAL MODE FOR TRANSPARENT TARPAULINS The photocell is able to differentiate between an interruption caused by an object and the movement of the door For this mode to work properly the bottom of the tarpaulin must...

Страница 10: ...4 Test response time 30 ms T5 Reboot time 100 ms T6 Test time 100 ms minimum Power supply T6 TEST V GND NC NO V GND Object No Object Test input Object detection Output Relay CHANGE OPERATING MODE Photocell Status LED Sector Status LEDs To select the next Operating Mode follow these steps 01 Turn off the power supply photocells 02 On the photocell receiver RX cover sensors 6 and 9 from the top and ...

Страница 11: ...LED Off Fast flashing LED 05 OPERATION Green LED Yellow LED Photocell Status The light curtain is functional No communication between photocells Test input off Without power Green LED Red LED Sector State Clear sector Obstructed sector Green LED Photocell Status With power Without power LED SIGNALING Photocell RECEIVER RX Photocell EMITTER TX LED On LED Off Blinking LED Photocell Status Sector 5 L...