AUTOMATIC TRACTION SYSTEM FOR OVERHEAD AND SECTIONAL DOORS

1   - VER unit
2   - Incorporated control panel 
3   - Radio receiver
4   - Internal pushbutton array
5   - Safety photocells
6   - Rubber safety section

Standar installation

SERIE

 

VER 

7   - Transmission arm
8   - Release mechanism
9   - Antenna
10 - Flashing light
11 - Key-operated selector switch

Содержание V900E

Страница 1: ...2 3 1 8 7 11 6 6 4 5 119ET44 GB AUTOMATIC TRACTION SYSTEM FOR OVERHEAD AND SECTIONAL DOORS 1 VER unit 2 Incorporated control panel 3 Radio receiver 4 Internal pushbutton array 5 Safety photocells 6 Rubber safety section Standar installation SERIE VER 7 Transmission arm 8 Release mechanism 9 Antenna 10 Flashing light 11 Key operated selector switch ...

Страница 2: ...over with window for lamp to illuminate the area The unit is mounted on and supported by the sliding rail Built in electric control panel Electronically run Encoder end stop Galvanised cold formed plate sliding rail front tensioning and fastening wall terminal ABS back motor unit support and connector terminal The rail has a built in emergency release device and the transmission arm s hook the rai...

Страница 3: ...artially inward entry type SPRING BALANCED OVERHEAD DOOR spring balanced outward vertical stroke and totally inward entry type SECTIONAL DOOR single sliding rail double sliding rail UNIT ASSEMBLY PREARRANGEMENT OF TRANSMISSION RAIL Fasten the bracket to the transmission guide s front terminal with the screws provided ...

Страница 4: ...e maximum door sliding point fig 2 and consequently fasten the bracket on high with adequate screws or rivets N B for counterweighted overhead doors partial entry it is necessary to use the adapter arm V201 read the technical documentation provided with the accessory Raise and set the guide horizontally to establish the distance from the ceiling then fasten the angle sections or fastening brackets...

Страница 5: ...move the automation container cover by unscrewing the ø3 9x13 screw Fasten the gear motor to the sliding rail s back terminal in the desired position with the three ø6 3x45 screws provided RELEASING THE GEARMOTOR Turn the release handle as illustrated the release will re hitch automatically at the first manoeuvre by returning the lever to its start position If there is a V121 cable release device ...

Страница 6: ...functions Automatic closing The automatic closing timer is automatically activated at the end of the opening cycle The preset adjustable automatic closing time is automatically interrupted by the activation of any safety system and is deactivated after a STOP command or in case of power failure Caution Shut off the mains power and disconnect the batteries before servicing the inside of the unit ZL...

Страница 7: ...CLOSE STOP Antenna connection ELECTRICAL CONNECTIONS N B All the contacts and push buttons normally closed N C that are not used must be short circuited Trimmer T C A Automatic closing time adjustment N B by adjusting the minimum the automatic closure function is excluded Trimmer SENS Amperometric sensitivity adjustment 1 ON Encoder programming it enables the procedure for the calibration of the o...

Страница 8: ...CC 3 15A FUS CENTR 315mA APRE AP CH AF 26V17V 0V M N E ENC RADIO ENCODER PROGRAMMING IMPORTANT READ INSTRUCTIONS CAREFULLY BEFORE PROCEEDING WITH PROGRAMMING closure limit switch Set dip switch 1 to ON the red LED comes on at slow intermittence Keep the AP CH button pressed and allow the overhead door to reach the limit switch when it closes Press and release the ENC RADIO button the signalling LE...

Страница 9: ...unner and secure it with the screws Set dip switch 1 to OFF Note if the LED indicator begins to flash rapidly after dip 1 has been reset it is necessary to repeat the procedure from the start NOTES After having programmed and switched dip 1 to OFF use the AP CH key to check proper gate opening and closing During programming make sure the closing end stop has been previously memorised otherwise the...

Страница 10: ...rd insertion Frequency MHz Radiofrequency board Transmitter FM 26 995 AF130 TFM FM 30 900 AF150 TFM AM433 92 AF43S AF43SM TAM TOP AF43SR ATOMO On AM transmitters operating at 433 92 MHz TOP and TAM series position the jumper connection on circuit card AF43S as shown on the sheet The AF board should ALWAYS be inserted when the power is off because the motherboard only recognises it when it is power...

Страница 11: ... C and channel to D P1 CH1 and P2 CH2 default setting The unit does not require specific maintenance However it is a good idea to periodically oil the sliding wheels and the pins of the door arms and to check the chain s tension PERIODIC MAINTENANCE C Code storage Keep the ENC RADIO key pressed on the base card the signal LED will flash and with a key on the transmitter the code is sent the LED wi...

Страница 12: ... 4940 fax 39 0422 4941 internet www came it e mail info came it Hereby declare under their own respons ibility that the product s called comply with the Italian National Legal Provisions that transpose the following Community Directives where specifically applicable MACHINERY DIRECTIVE 98 37 CE LOW VOLTAGE DIRECTIVE 73 23 EEC 93 68 EEC LECTROMAGNETIC COMPATIBILITY DIRECTIVE 89 336 EEC 92 31 EEC R ...